首页> 外文期刊>Water Science and Technology >Treatment of high-strength pharmaceutical wastewater by electrocoagulation combined with anaerobic process
【24h】

Treatment of high-strength pharmaceutical wastewater by electrocoagulation combined with anaerobic process

机译:电凝-厌氧法处理高强度制药废水

获取原文
获取原文并翻译 | 示例
           

摘要

This article discusses a combined treatment system comprising electrocoagulation (EC) as a pre-treatment followed by anaerobic fixed film fixed bed reactor (AFFBR) for treatment of high strength pharmaceutical wastewater. The effect of various operating parameters such as pH, current density and electrolysis duration on COD, BOD and colour removal was studied. The maximum removals for COD, BOD and colour under optimal operating conditions i.e. pH 7.2, current density (CD) of 80 A/m(2) and electrolysis time of 25 minutes were 24%, 35% and 70.25% respectively. Increase in current density has resulted in decrease in electrolysis duration with marginal improvement in treatment efficiency. The efficiency of removal is discussed in terms of kgCOD(r)A(-1) m(-2) h(-1) and energy consumption as Wh kg(-1) CODr. The effluents obtained after EC were treated by AFFBR at various organic loading rates (OLRs) and hydraulic retention times (HRTs). The results indicated removals in the range of 80-90% for COD and 86-94% for BOD respectively, at OLRs between 0.6 to 4.0 Kg COD/m(3) d at an HRT of 2 days. The total gas quantity increased with increase in both HRT and OLR up to a loading of 6 Kg COD/m(3)/d but it did not commensurate with organic load. The results indicated that the combined treatment option is competitive and can be used effectively for high strength wastewaters.
机译:本文讨论了一种组合处理系统,该系统包括电凝(EC)作为预处理,然后是厌氧固定膜固定床反应器(AFFBR),用于处理高强度制药废水。研究了pH,电流密度和电解时间等各种操作参数对COD,BOD和脱色的影响。在最佳操作条件下,即pH 7.2,电流密度(CD)为80 A / m(2)和25分钟的电解时间,COD,BOD和颜色的最大去除率分别为24%,35%和70.25%。电流密度的增加导致电解时间的缩短,同时处理效率略有提高。去除效率以kgCOD(r)A(-1)m(-2)h(-1)和能耗为Wh kg(-1)CODr的形式进行讨论。 EC后获得的废水通过AFFBR在各种有机负荷率(OLR)和水力停留时间(HRT)下进行处理。结果表明,在HRT为2天的情况下,在0.6至4.0 Kg COD / m(3)d的OLR下,COD的去除率分别为80-90%和BOD的去除率为86-94%。总气体量随HRT和OLR的增加而增加,直至达到6 Kg COD / m(3)/ d的负荷,但与有机负荷不相称。结果表明,组合处理方案具有竞争力,可有效用于高浓度废水。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号