In 2000 the European Union introduced the Water Framework Directive (WFD). The aim of the WFD is having an ecological and chemical balance for all surface waters in Europe in 2015. The European Commission identified 33 priority substances and their maximum allowable concentrations, FHI-values (Fraunhofer Institute), which are specified in the Annex of the WFD. The objective of this research is to achieve the removal of suspended solids, nitrogen and total phosphorus together with priority substances. All these substances will be removed in one filter called a “One Step Total Effluent Polishing filter” i.e. 1-STEP~? filter. For this purpose a filter pilot plant was tested at the WWTP Horstermeer. The results show that the filter can fulfil the target values in the filtrate water for total nitrogen (2.2mg Ntotal/L) and total phosphorus (0.15mg Ptotal/L). The majority of the priority (hazardous) substances in the WWTP effluent are already below the detection limit. Due to the low concentration ranges, the results on the removal of medicine and pesticides are only indicative. A decreasing tendency in the removal efficiency is shown for all measured compounds. The average specific ultrafiltration resistance (SUR) value decrease of the filter is 55% and the final value is always below 5·10~(12)m~(-2). This indicates that the filtrate water of the filter is very well filterable and can be used as ultrafiltration feedwater.
机译:欧盟于2000年推出了水框架指令(WFD)。 WFD的目标是在2015年实现欧洲所有地表水的生态和化学平衡。欧盟委员会确定了33种优先物质及其最大允许浓度FHI值(弗劳恩霍夫研究所),在附录中指定。世界粮食日。这项研究的目的是实现去除悬浮固体,氮和总磷以及优先物质。所有这些物质将通过一个称为“一步总废水抛光过滤器”的过滤器(即1-STEP〜?)除去。过滤。为此,在污水处理厂Horstermeer对一个过滤器中试装置进行了测试。结果表明,该滤池可以满足滤液水中总氮(总Nmg 2.2L / L,总磷0.15mg Ptotal / L)的目标值。污水处理厂废水中的大多数优先(有害)物质已经低于检出限。由于浓度范围低,药物和农药去除的结果仅是指示性的。对于所有测得的化合物,去除效率都有下降的趋势。过滤器的平均比超滤阻力(SUR)值降低55%,最终值始终低于5·10〜(12)m〜(-2)。这表明过滤器的滤液水可很好地过滤,可以用作超滤给水。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号