PURPOSE: This prospective randomized controlled trial aimed to compare single implant-supported mandibular molar restorations using either an immediate or a delayed loading protocol. MATERIALS AND METHODS: Thirty subjects requiring single mandibular molar replacement were consecutively treated. One implant was placed in each patient. Fifteen subjects were assigned to delayed loading protocol and 15 to immediate loading protocol according to a randomization table. After insertion, the delayed loaded implants were connected to a healing abutment and restored after 3 to 4 months of healing without loading. The immediately loaded implants were loaded within 24 hours of surgery with a provisional restoration. The interim prosthesis was placed in centric occlusion. All contacts in lateral excursions were eliminated. At implant placement the maximum value of insertion torque was recorded. Radiographic bone level change was measured on periapical radiographs obtained at the time of implant placement and 12 months after loading. Means of the 2 groups were compared by Student t test and analysis of variance (ANOVA). The level of significance was set at .05. RESULTS: No implants were lost in the delayed loading group (0/15), whereas 1 implant failed (1/15) in the immediate loading group. No differences were observed in relation to implant length or insertion torque between the groups. The average radiographic bone level change after 1 year of function was 1.2 +/- 0.55 mm (range, 0.5 to 2.6 mm) and 0.77 +/- 0.38 mm (range, 0.29 to 1.23 mm) for the delayed loaded and the immediately loaded implants, respectively. The difference in radiographic bone level change between the delayed and immediate loading groups was statistically significant (P = .022; CI = -0.79 to -0.06; Student t test). CONCLUSIONS: Immediate loading of wide-diameter implants supporting single restorations in mandibular molar sites seems to be a suitable clinical option. Moreover, the radiographic bone level change observed after 12 months of loading was significantly less for immediately loaded implants.
机译:目的:这项前瞻性随机对照试验旨在比较使用即刻加载或延迟加载方案的单个种植体支持的下颌磨牙修复体。材料与方法:连续治疗30名需要单下颌磨牙置换的受试者。每个患者中放置一个植入物。根据随机对照表,将15名受试者分配为延迟负荷方案,将15名受试者分配为立即负荷方案。插入后,将延迟加载的植入物连接至愈合基台,并在愈合3至4个月后恢复无负载状态。立即加载的植入物在手术后24小时内加载,并进行临时修复。临时假体置于中心闭塞。消除了横向偏移中的所有接触。在植入物放置时,记录插入扭矩的最大值。在种植体植入时和加载12个月后在根尖周片上测量放射线骨水平变化。通过学生t检验和方差分析(ANOVA)比较两组的平均值。显着性水平设置为0.05。结果:延迟加载组(0/15)中没有植入物丢失,而立即加载组中有1个植入物失败(1/15)。两组之间在植入物长度或插入扭矩方面均未观察到差异。功能延迟1年后,延迟加载和立即加载的植入物的平均放射线骨水平变化为1.2 +/- 0.55毫米(范围为0.5至2.6毫米)和0.77 +/- 0.38毫米(范围为0.29至1.23毫米) , 分别。延迟负荷组和立即负荷组之间的放射学骨水平变化差异具有统计学意义(P = .022; CI = -0.79至-0.06; Student t检验)。结论:立即加载支持单个修复体的大直径植入物在下颌磨牙部位似乎是一种合适的临床选择。而且,对于立即加载的植入物,在加载12个月后观察到的射线照相骨水平变化明显更少。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号