Increased intraosseous temperature caused by ultrasonic devices during bone surgery and the influences of working pressure and cooling irrigation.

机译:骨外科手术中由超声设备引起的骨内温度升高,以及工作压力和冷却冲洗的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The purpose of this study was to investigate the increases in intraosseous temperature generated by a modern ultrasonic device for bone surgery (UDBS) and the influences of working pressure and cooling irrigation on this temperature.Twenty human mandibular bone specimens (20x15x5 to 7 mm) were used; three vertical cuts were performed for a duration of 12 seconds per cut. Each bone specimen was machined with a different combination of working pressure (1.5, 2.0, 3.0, 4.0, or 6.0 N) and cooling irrigation (0, 30, 60, or 90 mL/min), and intraosseous temperatures were measured. Harmful temperature development was defined as an increase of more than 10°C for the 75th percentile and/or a maximum increase of more than 15°C. Cutting performance was also measured.Harmless intraosseous temperature development was identified for working pressures of 1.5 N and 2.0 N with cooling irrigations of 30, 60, and 90 mL/min and for 3.0 N at 90 mL/min. The maximum temperature observed was 72°C (6.0 N with 60 mL/min). The mean cutting performance values were 0.21±0.02 mm/s for 6.0 N, 0.21±0.06 mm/s for 3.0 N, 0.20±0.01 mm/s for 4.0 N, 0.11±0.05 mm/s for 1.5 N, and 0.08±0.03 mm/s for 2.0 N.To prevent tissue damage in dental bone surgery, a minimum coolant amount of 30 mL/min is recommended. The working pressure should be chosen with great care because of its significant influence on intraosseous temperature. Doubling of the working pressure from 1.5 to 3.0 N requires a tripling of the coolant (30 to 90 mL/min) to prevent tissue damage. A working pressure above 3.0 N did not result in improved cutting performance.
机译:这项研究的目的是研究现代骨外科超声设备(UDBS)产生的骨内温度升高以及工作压力和冷却冲洗对这一温度的影响.20个人类下颌骨标本(20x15x5至7 mm)用过的;进行三个垂直切割,每次切割持续12秒。用不同的工作压力(1.5、2.0、3.0、4.0或6.0 N)和冷却冲洗(0、30、60或90 mL / min)的组合对每个骨骼标本进行机械加工,并测量骨内温度。有害的温度升高定义为第75个百分位数的升高超过10°C和/或最高升高超过15°C。还测量了切削性能。在工作压力为1.5 N和2.0 N,冷却冲洗速度为30、60和90 mL / min的情况下以及在90 mL / min的温度为3.0 N的情况下,确定了无伤害的骨内部温度发展。观察到的最高温度为72°C(6.0 N,60 mL / min)。平均切削性能值为6.0 N为0.21±0.02 mm / s,3.0 N为0.21±0.06 mm / s,4.0 N为0.20±0.01 mm / s,1.5 N为0.11±0.05 mm / s和0.08±0.03 mm / s,2.0N。为防止在牙科骨手术中损坏组织,建议最低冷却剂量为30 mL / min。应谨慎选择工作压力,因为它会对骨内温度产生重大影响。 1.5至3.0 N的工作压力加倍需要冷却液加倍(30至90 mL / min)以防止组织损伤。高于3.0 N的工作压力并不能改善切削性能。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号