To determine whether a wire-guided single drill protocol could be utilized without causing an increase in bone temperature beyond those seen with the traditional techniques of sequential drilling with and without a drill guide.A bovine femoral bone model was used with thermocouples and infrared temperature measurements to record thermal increase of the bone and drills during implant site preparation. Two thermocouples, one on each side of the osteotomy, were placed 1 mm from the outer diameter of the final drill. Drilling was performed at a constant speed (2,100 rpm) and pressure (2 kg) under continuous room temperature irrigation. Infrared temperature measurements of each drill were taken immediately before and after drilling. The six study groups included standard sequential drilling protocols for 3.5-mm and 4.2-mm final drills with and without the use of a surgical guide, and cannulated single drill technique for 3.5-mm and 4.2-mm drills. Statistical analysis was performed using a Tukey post hoc one-way ANOVA test. P<.05 was determined to be significant.No significant difference in thermal increase was found between single drill cannulated implant site preparation and sequential drilling with or without the use of a drill guide for the 3.5-mm or 4.2-mm drilling sequences, respectively. The thermal increase was found to be significantly less for the 4.2-mm single drill compared with the 3.5-mm sequential drill with surgical guide (P=.046). Infrared temperature measurement revealed no significant difference in drill temperatures throughout the study.Cannulated single drill technique does not cause an increase in bone temperature greater than that seen with standard sequential drilling with or without a surgical guide.
机译:为了确定是否可以使用线引导的单钻协议而不会导致骨温升高超过传统的有序钻和无钻导引的顺序钻技术所观察到的情况。牛股骨模型用于热电偶和红外温度测量记录植入部位准备过程中骨骼和钻头的热量增加。将两个热电偶(在截骨的每一侧各放置一个)放置在距离最终钻头外径1 mm处。在连续的室温灌溉下,以恒定速度(2,100 rpm)和压力(2 kg)进行钻孔。在钻进之前和之后立即进行每个钻的红外温度测量。六个研究小组包括在3.5毫米和4.2毫米最终钻的情况下使用和不使用手术导向器的标准顺序钻孔方案,以及在3.5毫米和4.2毫米钻头中使用空心单钻技术。使用Tukey事后事后单向方差分析进行统计分析。 P <.05被认为是显着的。在3.5mm或4.2mm的钻孔顺序下,在单钻空心种植体位准备和顺序钻孔中(无论是否使用钻头导向器)的热增加之间均未发现显着差异。 。发现与使用手术引导的3.5毫米顺序钻相比,4.2毫米单钻的热增加明显更少(P = .046)。红外温度测量显示整个研究期间的钻头温度没有显着差异。单孔钻头技术不会导致骨骼温度的增加大于使用或不使用手术引导器的标准顺序钻孔所观察到的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号