...
首页> 外文期刊>The International journal of oral & maxillofacial implants >The positions of implant heads in relation to the fixed dental prosthesis: a comparison of multiple zygomatic implants with standard implants for the reconstruction of the atrophic maxilla.
【24h】

The positions of implant heads in relation to the fixed dental prosthesis: a comparison of multiple zygomatic implants with standard implants for the reconstruction of the atrophic maxilla.

机译:种植体头部相对于固定义齿的位置:多个骨种植体与标准种植体用于萎缩性上颌骨重建的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to investigate the positions of dental implants at the crestal level and the occlusal level of a fixed dental prosthesis (FDP) in severely and moderately resorbed maxillae. Restorations supported by multiple zygomatic implants were compared with restorations supported by standard implants.Between 2004 and 2007, measurements were performed on FDPs and working casts. Two groups were investigated: (1) patients with severe atrophy and extensive resorption into basal bone treated with multiple zygomatic implants (Zyg) and (2) patients with moderate atrophy with standard implants only (Stand). The areas bounded by the FDP at the implant level (A(impl)) and at the occlusal level (A(prost)) were calculated, and A(prost) -A(impl) represented the total horizontal overjet of the FDP. A(prost)/A(impl) was established as the degree of overlapping of these two areas. The transverse and sagittal dimensions at the implant level (T(impl) and S(impl)) and at the occlusal level (T(prost) and S(prost)) were also measured. T(impl)/S(impl) and T(prost)/S(prost) represented the shape of the superstructure at these respective levels.Seven consecutive patients in the Zyg group were matched by age and gender with seven individuals in the Stand group. In the Zyg group, 28 zygomatic and 5 standard implants were placed; in the Stand group, 41 standard implants were placed, of which 3 were lost. All patients received an FDP. T(impl) was shorter and S(impl) was longer in the Zyg group, yielding a smaller T(impl)/S(impl) in this group. The Zyg group also displayed less overjet and a smaller A(prost)/A(impl) compared to the Stand group.Multiple zygomatic implants emerged through the residual crest with a more even distribution in the sagittal plane compared to standard implants and with a better congruence with the occlusal location of the FDP.
机译:这项研究的目的是研究在严重和中度吸收的上颌骨中牙种植体在固定水平和固定状态的牙顶位置和咬合水平。将多个骨种植体支持的修复体与标准种植体支持的修复体进行了比较.2004年至2007年之间,对FDP和工作石膏进行了测量。研究了两组:(1)使用多个multiple骨植入物(Zyg)治疗的严重萎缩和广泛吸收进入基底骨的患者,以及(2)仅使用标准植入物(Stand)的中度萎缩患者。计算在植入物水平(A(impl))和咬合水平(A(prost))上受FDP限制的面积,并且A(prost)-A(impl)代表FDP的总水平过喷射量。建立A(prost)/ A(impl)作为这两个区域的重叠程度。还测量了植入物水平(T(impl)和S(impl))和咬合水平(T(prost)和S(prost))的横向和矢状尺寸。 T(impl)/ S(impl)和T(prost)/ S(prost)分别代表上层结构的形状.Zyg组的7例连续患者按年龄和性别进行了匹配,Stand组的7例。在Zyg组中,放置了28个go骨和5个标准植入物。在“站立”组中,放置了41个标准植入物,其中3个丢失。所有患者均接受了FDP。 Zyg组中T(impl)较短,而S(impl)较长,因此该组中的T(impl)/ S(impl)较小。与Stand组相比,Zyg组还显示出较少的过喷射和较小的A(prost)/ A(impl)。与标准种植体相比,多个zy骨种植体通过残留c突在矢状面分布更均匀与FDP的咬合位置一致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号