首页> 外文期刊>The International journal of oral & maxillofacial implants >Microbial contamination and the sterilization/disinfection of surgical guides used in the placement of endosteal implants.
【24h】

Microbial contamination and the sterilization/disinfection of surgical guides used in the placement of endosteal implants.

机译:微生物污染和用于植入骨内植入物的外科手术器械的灭菌/消毒。

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The purpose of this study was twofold: (1) to estimate the level of microbial contamination found on commercial guides (CG) and in-house laboratory guides (LG) prior to use, and (2) to evaluate the antimicrobial potential of disinfectants commonly used in dentistry to decontaminate heat-sensitive surgical guides. Ethylene oxide gas was used as the positive control; sterile water served as a negative control. Materials and Methods: Evaluation of CGs and LGs for bacterial contamination occurred soon after their arrival in the laboratory. Some guides went directly into tubes of trypticase soy broth solution, vortexed and equally divided into two tubes. One tube went into an 80 degrees C bath for 19 minutes, while the other stayed at room temperature. After plating, half of the samples underwent anaerobic incubation. All incubation was for 48 hours at 37 degrees C. Other guides underwent water rinsing or disinfection by various methods for 5 or 15 minutes or ethylene oxide gas sterilization prior to sampling. Results: Untreated CG specimens showed modest levels of bacterial contamination, with most colonies coming from liquid specimens not exposed to 80 degrees C. LG specimens had more bacteria from both heat-treated and non-heat-treated aliquots. Chlorhexidine gluconate, diluted bleach, and water rinsing were not able to completely eliminate microorganisms on the specimens, but no viable microorganisms were present on specimens treated with gas sterilization or 70% ethanol for 15 minutes. Conclusion: CGs and LGs, on average, had different levels of bacterial contamination prior to disinfection. Water, chlorhexidine gluconate, and diluted bleach were not totally successful in decontaminating the surgical guides, but no growth was found after 15 minutes of immersion in 70% ethanol. Preferably, surgical guides should be submerged in 70% alcohol for a minimum of 15 minutes or undergo sterilization using ethylene oxide gas. Int J Oral Maxillofac Implants 2011;26:274-281.
机译:目的:本研究的目的是双重的:(1)评估使用前在商业指南(CG)和内部实验室指南(LG)上发现的微生物污染水平,以及(2)评估该产品的抗菌潜力牙科中常用的消毒剂对热敏感的外科手术器械进行消毒。环氧乙烷气体用作阳性对照;无菌水用作阴性对照。材料和方法:评估CG和LG进入实验室后不久就进行了细菌污染评估。一些指南直接进入了胰酶解大豆肉汤溶液试管,涡旋振荡,并均等地分为两个试管。一个管子在80摄氏度的浴缸中浸泡19分钟,而另一个则保持在室温下。电镀后,一半样品进行厌氧培养。全部孵育在37摄氏度下进行48小时。其他指南在取样前通过各种方法用水漂洗或消毒5或15分钟,或进行环氧乙烷气体灭菌。结果:未经处理的CG标本显示中等程度的细菌污染,其中大多数菌落来自未暴露于80摄氏度的液体标本。LG标本的热处理和未热处理等分试样细菌含量均较高。葡萄糖酸氯己定,稀释的漂白剂和水漂洗不能完全消除样品上的微生物,但是用气体灭菌或70%乙醇处理15分钟的样品上没有可生存的微生物。结论:消毒前,CGs和LGs平均具有不同水平的细菌污染。水,葡萄糖酸氯己定和稀释的漂白剂不能完全成功地净化外科手术指南,但在70%的乙醇中浸泡15分钟后没有发现生长。手术指南最好浸入70%的酒精中至少15分钟,或使用环氧乙烷气体进行灭菌。 Int J口腔Maxillofac植入物2011; 26:274-281。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号