Effects of repeated manual disassembly and reassembly on the positional stability of various implant-abutment complexes: an experimental study.

机译:反复手动拆卸和重新组装对各种种植体-基台复合体位置稳定性的影响:一项实验研究。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The purpose of this study was to evaluate rotational, vertical, and canting changes in the position of the rotation-safe component in the implant-abutment assemblies of five different implant systems (ITI, Steri-Oss, Camlog, Astra Tech, and Replace Select) after manual removal and reassembly. MATERIALS AND METHODS: Prefabricated stainless steel models were used for each implant system, into which six implants were fixated with polymethylmethacrylate resin. Rotation-safe abutments (components) were screwed into the implants according to the manufacturers' specifications. Three test persons with varying knowledge of the theory and practice of implant dentistry manually assembled and reassembled the implant-abutment joint using each system-specific screwdriver 20 times each. A coordinate reading machine was used to detect discrepancies in position after each reassembly in relation to a coordinate system. Rotational freedom, changes in vertical height, and deviations in angulation were assessed. Statistical analysis was performed based on the nonparametric analysis of variance of repeated measurements. RESULTS: The tested complexes showed rotational freedom that ranged from 0.92 to 4.92 degrees, with significant differences between the systems. Camlog was significantly different from all other systems tested regarding rotational freedom, whereas Steri-Oss, Astra Tech, and Replace Select showed no significant difference between each other because of their nondiscrepant mean degree of rotational freedom. Vertical alterations in position ranged from 1 to 83 microm. A statistically significant difference was detected between butt-joint and beveled implant-abutment connections, with ITI and Astra Tech showing no significant difference when compared to each other, but displaying a significant difference versus all other systems tested. Canting discrepancies were not significant, with no influence of implant system or test person clearly detectable. CONCLUSION: Three-dimensional changes in the location of the abutment in relation to the implant result after manual assembly and reassembly of the implant-abutment complex.
机译:目的:本研究的目的是评估五个不同植入系统(ITI,Steri-Oss,Camlog,Astra Tech和手动拆卸并重新组装后,请更换Select)。材料与方法:每个植入系统使用预制的不锈钢模型,其中六个植入物用聚甲基丙烯酸甲酯树脂固定。根据制造商的说明,将防旋转基台(组件)拧入植入物。三名具有不同种植牙学理论和实践知识的测试人员使用每个系统专用螺丝刀手动组装和重新组装了种植体-基台关节,每次20次。坐标读取机用于检测每次重新组装后相对于坐标系的位置差异。评估了旋转自由度,垂直高度的变化以及角度的偏差。基于重复测量方差的非参数分析,进行统计分析。结果:测试的配合物显示出0.92至4.92度的旋转自由度,系统之间存在显着差异。 Camlog在旋转自由度方面与测试的所有其他系统都存在显着差异,而Steri-Oss,Astra Tech和Replace Select在彼此之间没有显着差异,因为它们的旋转自由度无差异。位置的垂直变化范围为1到83微米。在对接和斜角种植体-基台连接之间检测到统计学上的显着差异,ITI和Astra Tech彼此之间没有显着差异,但与所有其他测试系统相比,都显示出显着差异。倾斜差异不显着,没有明显可检测到植入物系统或测试人员的影响。结论:在人工组装和重新组装种植体-基台复合体后,基台相对于种植体的位置发生了三维变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号