The aims of this study were to establish a normal reference range (mean+or-2 SD) and assess reliability of renal dimensions obtained using transabdominal ultrasonography in Thoroughbred horses (n=7). A minimum of three ultrasonographic cineloops were obtained from each intercostal space and the left paralumbar fossa by two observers daily for three consecutive days. Renal length, width, and thickness and cortex, medulla, and pelvic dimensions were obtained. Measurements were undertaken by both observers, who were unaware of prior measurements, to assess reproducibility and measured on three separate occasions to evaluate short-term measurement repeatability. Measurements from images obtained by both operators were compared to evaluate image repeatability. The left kidney was consistently identified in the left 15th-17th intercostal space and the paralumbar fossa with maximal length in the 16th intercostal space (12.7+or-2.0 cm) and maximal width in the paralumbar fossa (7.9+or-1.1 cm). The right kidney was consistently identified in the right 15th-17th intercostal space with maximal length and maximal width in the 15th intercostal space (16.0+or-0.7 cm and 7.9+or-1.0 cm). Reproducibility, image repeatability, measurement repeatability were good to excellent, although were less good for the smaller structures. There were no differences in renal dimensions between horses. Overall renal ultrasonography was reliable and a normal reference range for Thoroughbred horses was established. Renal dimensions vary between rib spaces. As repeatability and reproducibility were excellent for renal length and width, it may be prudent to use those measurements in rib spaces where parameters were maximal.
机译:这项研究的目的是建立一个正常的参考范围(平均值±2 SD),并评估经腹超声对纯种马的肾脏尺寸的可靠性( n = 7)。每天由两名观察员连续三个天从每个肋间空间和左腰椎旁窝中至少获取三个超声电影电影。获得了肾脏的长度,宽度和厚度以及皮质,髓质和骨盆尺寸。两位观察员进行了测量,他们不知道先前的测量,以评估可重复性,并在三个不同的场合进行测量以评估短期测量的可重复性。比较两个操作员从图像获得的测量结果,以评估图像的可重复性。左肾在第15-17肋间间隙和腰椎旁窝始终被识别,最大长度在第16肋间间隙(12.7+或-2.0 cm),最大宽度在副腰窝(7.9+或-1.1 cm)。右肾在第15-17肋间右间隙中始终被识别,在第15肋间间隙中最大长度和最大宽度(16.0+或-0.7 cm和7.9+或-1.0 cm)。重现性,图像可重复性,测量可重复性均好至极,尽管对于较小的结构却不太好。马之间的肾脏尺寸没有差异。总体肾脏超声检查是可靠的,并建立了纯血马的正常参考范围。肾的尺寸在肋骨空间之间变化。由于对于肾脏的长度和宽度而言,重复性和可重复性极好,因此在参数最大的肋骨空间中使用这些测量方法可能是明智的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号