Commonly used clinical indicators of renal disease are either insensitive to early dysfunction or have delayed results. Decreased glomerular filtration rate (GFR) indicates renal dysfunction before there is a loss of 50% of functional nephrons. Most tests evaluate global rather than individual kidney function. Dynamic computed tomography (CT) and Patlak plot analysis allows for individual GFR to be tested. Our objectives were to establish a procedure and provide reference values for determination of global GFR in 10 healthy cats using dynamic CT (CTGFR). This method of GFR determination was compared against serum iohexol clearance (SIC). A single CT slice centered on both kidneys and the aorta was acquired every fifth second during and after a bolus injection of iohexol (240 mgI/ml; 300 mgI/kg) for 115 s. Using data from this dynamic acquisition, Patlak plots were obtained, GFR was calculated, and results were compared to global GFR determined by iohexol clearance. The average global CTGFR estimate was 1.84 ml/min x kg (SD=0.43; range=[1.22, 2.45]). The average global GFR measured using SIC was 2.45 ml/min x kg (SD=0.58; range=[1.72, 3.69]). GFR measurements estimated by both dynamic CT and SIC were positively associated (estimated Spearman rank correlation coefficient=0.72; P=0.0234). The CTGFR method consistently underestimated GFR with a bias of -0.62 (SE=0.1307) when compared to SIC (P=0.0011). In healthy cats, CTGFR was capable of determining individual kidney function and appears clinically promising.Digital Object Identifier http://dx.doi.org/10.1111/j.1740-8261.2011.01899.x
机译:肾脏疾病的常用临床指标对早期功能障碍不敏感或结果延迟。肾小球滤过率(GFR)降低表示肾功能不全,然后失去功能性肾的50%。大多数测试评估的是整体肾功能而不是个人肾功能。动态计算机断层扫描(CT)和Patlak图分析可对单个GFR进行测试。我们的目标是建立一种程序,并为使用动态CT(CTGFR)测定10只健康猫的总GFR提供参考值。将这种GFR测定方法与血清碘海醇清除率(SIC)进行了比较。大剂量注射碘海醇(240 mgI / ml; 300 mgI / kg)115 s期间和之后,每五秒钟采集一次以肾脏和主动脉为中心的CT切片。使用来自该动态采集的数据,获得Patlak图,计算GFR,并将结果与​​通过碘海醇清除率确定的总体GFR进行比较。平均全球CTGFR估计值为1.84 ml / min x kg(SD = 0.43;范围= [1.22,2.45])。使用SIC测量的平均总GFR为2.45 ml / min x kg(SD = 0.58;范围= [1.72,3.69])。动态CT和SIC估计的GFR测量值呈正相关(估计的Spearman等级相关系数= 0.72; P = 0.0234)。与SIC( P = 0.0011)相比,CTGFR方法始终低估GFR,其偏差为-0.62(SE = 0.1307)。在健康的猫中,CTGFR能够确定个体的肾功能,并且在临床上似乎很有希望。数字对象标识符http://dx.doi.org/10.1111/j.1740-8261.2011.01899.x

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号