MAGNETIC RESONANCE SIGNAL CHANGES DURING TIME IN EQUINE LIMBS REFRIGERATED AT 4pC

机译:4pC制冷的马匹肢体中磁共振信号随时间的变化

获取原文
获取原文并翻译 | 示例
           

摘要

When ex vivo magnetic resonance (MR) imaging studies are undertaken, specimen conservation should be taken into account when interpreting MR imaging results. The purpose of this study was to assess MR changes during time in the anatomic structures of the equine digit on eight cadaver limbs stored at 4pC. The digits were imaged within 12 h after death and then after 1, 2, 7, and 14 days of refrigeration. After the last examination, four feet were warmed at room temperature for 24 h and reimaged. Sequences used were turbo spin echo (TSE) T1, TSE T2, short tau inversion recovery (STIR), and double-echo steady state (DESS). Images obtained were compared subjectively side by side for image quality and signal changes. Signal-to-noise ratio (SNR) was measured and compared between examinations. There were no subjective changes in image quality. A mild size reduction of the synovial recesses was detected subjectively. No signal change was seen subjectively except for bone marrow that appeared slightly hyperintense in STIR and slightly hypointense in TSE T2 sequence after refrigeration compared with day 0. Using quantitative analysis, significant SNR changes in bone marrow of refrigerated limbs compared with day 0 were detected in STIR and TSE T2 sequences. Warming at room temperature for 24 h produced a reverse effect on SNR compared with refrigeration with a significant increase in SNR in TSE T2 images. After 14 days of refrigeration a statistically significant decrease of SNR was found in bone marrow in TSE T2 and DESS sequences. The SNR in the deep digital flexor tendon was not characterized by significant change in SNR.
机译:进行离体磁共振(MR)成像研究时,在解释MR成像结果时应考虑标本保存。这项研究的目的是评估在4pC下存储的8个尸体肢体的马手指解剖结构中的MR变化。数字在死亡后12小时内成像,然后在冷藏1、2、7和14天后成像。最后一次检查后,将四只脚在室温下加热24小时,然后重新成像。使用的序列是涡轮自旋回波(TSE)T1,TSE T2,短tau反转恢复(STIR)和双回波稳态(DESS)。并行比较获得的图像的图像质量和信号变化。测量信噪比(SNR),并在两次检查之间进行比较。图像质量没有主观变化。主观上检测到滑膜凹陷的大小有轻度减小。与第0天相比,除了冷藏后STIR T2序列中的STIR稍强,TSE T2序列中的稍低的骨髓外,主观上没有信号变化。通过定量分析,与第0天相比,冷藏肢体的SNR显着变化。 STIR和TSE T2序列。与冷藏相比,室温冷藏24小时对SNR产生了相反的影响,TSE T2图像中的SNR显着增加。冷藏14天后,在TSE T2和DESS序列的骨髓中发现SNR的统计显着下降。深屈指肌腱的SNR并未以SNR的显着变化为特征。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号