首页> 外文期刊>Veterinary Ophthalmology >Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits
【24h】

Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits

机译:反弹和压平眼压计测量正常家兔眼压的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Objective To compare intraocular pressure (IOP) measurements made on healthy adult rabbits without the effect of tranquilizers using the new applanation tonometer, Tono-Pen Avia (R), and the rebound tonometer Tonovet (R).Methods Intraocular pressure was measured throughout the day (6:00, 9:00, 12:00, 15:00, and 18:00 h) in 38 adult New Zealand White rabbits (76 eyes). The animals were 20 males and 18 females, with a mean weight of 3.5 kg and an average age of 6 months. A complete ocular exam (including Schirmer tear test, fluorescein staining, slit-lamp biomicroscopy, and direct ophthalmoscopy) was performed on all animals at the beginning of the trial. Rebound tonometry was performed, and after 10 min, anesthetic drops were instilled and applanation tonometry was carried out. IOP values obtained using the two techniques were analyzed statistically.Results The mean IOP was 9.51 +/- 2.62 mmHg with Tonovet (R), and 15.44 +/- 2.16 mmHg with the Tono-Pen Avia (R). Significant differences between measurements with the two tonometers were observed (P < 0.001). The linear regression equation describing the relationship between the two tonometers was y = 0.4923x + 10.754 (y = Tonovet (R) and x = Tono-Pen Avia (R)). High IOPs were recorded in the early measurements (6:00), but the average IOPs from both devices were statistically similar throughout the day (P = 0.086). The correlation coefficient was r(2) = 0.357. No significant difference in IOP regarding gender was observed.Conclusion The Tono-Pen Avia (R) recorded higher levels of IOP compared with the Tonovet (R). Early in the day, the IOP of rabbits was higher than later in the day, regardless of the tonometer used.
机译:目的使用新型压平眼压计Tono-Pen Avia(R)和回弹眼压计Tonovet(R)比较健康成年兔子在没有镇定剂作用下的眼压(IOP)。方法全天测量眼压(6:00、9:00、12:00、15:00和18:00 h)38只成年新西兰白兔(76眼)。动物为20头雄性和18头雌性,平均体重为3.5千克,平均年龄为6个月。在试验开始时,对所有动物进行了完整的眼科检查(包括Schirmer泪液试验,荧光素染色,裂隙灯生物显微镜检查和直接检眼镜)。进行回弹眼压计,并在10分钟后滴入麻醉滴剂并进行压平眼压计。统计分析了这两种技术获得的IOP值。结果Tonovet(R)的平均IOP为9.51 +/- 2.62 mmHg,Tono-Pen Avia(R)的平均IOP为15.44 +/- 2.16 mmHg。观察到两个眼压计的测量值之间存在显着差异(P <0.001)。描述两个眼压计之间关系的线性回归方程为y = 0.4923x + 10.754(y = Tonovet(R)和x = Tono-Pen Avia(R))。在早期测量(6:00)中记录到较高的IOP,但是一天中两种设备的平均IOP在统计上相似(P = 0.086)。相关系数为r(2)= 0.357。在性别方面,未观察到IOP的显着差异。结论与Tonovet(R)相比,Tono-Pen Avia(R)记录了更高的IOP水平。不论使用何种眼压计,在清晨时,兔子的IOP都比当天晚时高。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号