首页> 外文期刊>Veterinarni Medicina >A new device for the aspiration of follicular fluid for acid-base balance analysis in cattle
【24h】

A new device for the aspiration of follicular fluid for acid-base balance analysis in cattle

机译:一种牛卵泡液抽吸的新装置,用于牛的酸碱平衡分析

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to evaluate a new device for the ultrasound-guided transvaginal aspiration of follicular fluid for acid-base balance analysis (ABB set) in comparison with the original modified commercial OPU set. In the ABB set, an aspiration syringe was placed in the front part of the new tool's handle, next to the transducer, so as to enable direct collection of the sample into the syringe. To obtain a sufficient amount of testable fluid, reservoirs of urine (rubber balloons) were used for later aspiration under laboratory conditions in Experiment 1. Fifteen triads of samples (each triad with two punctures) were collected. While the first sample of each triad was taken using the ABB set (ABB sample), two samples were taken by one puncture using the original modified commercial OPU set: aerobic phase of sampling (AE sample) with air present in the tubing at the start of sampling and the subsequent anaerobic phase of sampling (AN sample). Values determined in the second sample from the triad (AE) varied from the values in both ABB and AN samples (pH 7.685 vs. 7.704 vs. 7.692, pCO_2 11.13 vs. 10.3 vs. 10.85, pO_2 6.87 vs. 8.67 vs. 7.02). In Experiment 2, ultrasound-guided transvaginal aspirations were carried out in 13 cows bearing ovarian cysts with diameters of at least 3 cm, using plastic aspiration syringes (Experiment 2P) and in 12 cows using glass aspiration syringes (Experiment 2G). The sequence of samples was the same as in Experiment 1. We found a significantly higher pH in AE in comparison to AN (7.357 vs. 7.348), lower pCO_2 (6l85) and higher O_2 (14.12) in samples of AE in comparison to samples of ABB and AN (pCO_2 7.36, 7.30; O_2 9.95, 10.63 respectively) in cystic fluid in Experiment 2P. We found a significantly higher pH(7.4), lower pCO_2 (5.98) and a higher pO_2 (12.35) in AE samples in comparison to ABB and AN samples of cystic fluid (pH 7.386, 7.385; pCO_2 6.39,6.35 and O_210.56,10.65, respectively) from Experiment 2G. We conclude that the acid-base balance assay wasaffected by air, present in the tubing during aerobic sampling in comparison to anaerobic and ABB set sampling. These pre-analytical changes can be prevented by the use of the ABB set because the results obtained with the ABB set were not different fromthat of the AN samples. We also confirmed pre-analytical changes in acid-base balance parameters in the cystic fluid after it had been stored in plastic aspiration syringes. Our new ABB set equipped with a glass aspiration syringe is suitable for sampling follicular fluid for both acid-base balance and gas analysis.
机译:这项研究的目的是与原始的改良型商用OPU装置相比,评估一种用于超声引导的经卵泡液阴道穿刺抽吸的新装置,以进行酸碱平衡分析(ABB装置)。在ABB套件中,将吸液注射器放置在新工具手柄的前部,靠近换能器,以便能够将样品直接收集到注射器中。为了获得足够量的可测试液体,在实验1的实验室条件下,将尿液(橡胶气球)用于以后的抽吸操作。收集了15个三联体样品(每个三联体有两个穿刺孔)。每个三合会的第一个样本使用ABB套件(ABB样本)采集,两个样本使用原始改良的商用OPU套件一次穿刺采集:有氧采样阶段(AE样本),开始时管路中存在空气采样以及随后的厌氧采样阶段(AN样本)。从三合一(AE)的第二个样品中确定的值与ABB和AN样品中的值都不同(pH 7.685对7.704对7.692对7.692,pCO_2 11.13对10.3对10.85,pO_2 6.87对8.67对7.02) 。在实验2中,使用塑料抽吸注射器(实验2P)在13头直径至少为3 cm的卵巢囊肿的母牛中进行了超声引导的经阴道抽吸术,并使用玻璃抽吸注射器(实验2G)在12头母牛中进行了超声引导下的阴道抽吸术。样品的顺序与实验1相同。我们发现AE中的AE中的pH值明显高于AN(7.357对7.348),AE样品中的pCO_2(6l85)和O_2(14.12)较低,与样品相比实验2P中的囊性液中ABB和AN的含量(分别为pCO_2 7.36、7.30; O_2 9.95、10.63)。我们发现AE样品中的pH值(7.4),pCO_2(5.98)和pO_2(12.35)明显高于ABB和AN的囊性液(pH 7.386、7.385; pCO_2 6.39、6.35和O_210.56,分别来自实验2G)。我们得出结论,与无氧和ABB固定采样相比,有氧采样期间管道中存在的空气对酸碱平衡测定产生了影响。通过使用ABB设置可以防止这些分析前的变化,因为使用ABB设置获得的结果与AN样品的结果没有区别。我们还确认了将囊性液体储存在塑料抽吸注射器中后,其在酸碱平衡参数方面的分析前变化。我们的新型ABB套件配有玻璃吸液注射器,适用于采样滤泡液,用于酸碱平衡和气体分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号