...
首页> 外文期刊>Veterinary Clinical Pathology >Canine differential leukocyte counting with the CellaVision DM96Vision, Sysmex XT-2000iV, and Advia 2120 hematology analyzers and a manual method
【24h】

Canine differential leukocyte counting with the CellaVision DM96Vision, Sysmex XT-2000iV, and Advia 2120 hematology analyzers and a manual method

机译:使用CellaVision DM96Vision,Sysmex XT-2000iV和Advia 2120血液分析仪对犬种白细胞进行计数和手动方法

获取原文
获取原文并翻译 | 示例
           

摘要

Background: For differential leukocyte counts, automated blood smear evaluation systems have been too slow or inaccurate to replace or supplement the manual differential count. The CellaVision DM96Vision (DM96V), a new instrument, is an automated image analysis system that is rapid and accurate enough to be used for enumerating human leukocytes and may be useful for analysis of canine blood.Objectives: The aims of this study were to evaluate the performance of the DM96V in differential counting of canine leukocytes, to compare its performance with that of other methods, and to analyze interoperator variability.Methods: Four methods of determining the leukocyte differential count of 108 canine blood samples were compared based on agreement, precision, and errors as well as relative performance. Differential counts were obtained using the DM96V, the manual method, and automated methods performed by the Advia 2120 and Sysmex XT-2000iV.Results: All leukocyte types were detected by the DM96V and the manual method, and all 4 methods had similar mean and median results in most cases. The automated methods were more precise than either the DM96V or manual method when comparing identification of a single type of leukocyte, especially neutrophils and lymphocytes. However, precision of the automated methods was only fair for monocytes, and the Advia and Sysmex failed to identify basophils. The Advia reported fewer monocytes and eosinophils than did the other methods. Significantly fewer lymphocytes were identified by the manual method than by the Sysmex, Advia, and DM96V. The DM96V occasionally presented duplicate images of the same neutrophils.Conclusions: The CellaVision DM96V is a satisfactory system for facilitating canine differential leukocyte counting. The DM96V differential count was more similar to the manual count than to automated counts, which were more precise but had errors and omissions in detecting some types of leukocytes.
机译:背景:对于白细胞计数的差异,自动血液涂片评估系统太慢或不准确,无法替代或补充人工差异计数。 CellaVision DM96Vision(DM96V)是一种新的仪器,是一种自动图像分析系统,该系统足够快速,准确,可用于枚举人类白细胞,可能对犬血的分析有用。 DM96V在犬白细胞差异计数中的性能,与其他方法进行比较,并分析互操作性差异。方法:比较了四种基于协议,精度确定108种犬血白细胞差异计数的方法,错误以及相对效果。使用DM96V,手动方法以及由Advia 2120和Sysmex XT-2000iV进行的自动化方法获得差异计数。结果:DM96V和手动方法检测了所有白细胞类型,并且所有4种方法的均值和中位数相似在大多数情况下都会产生结果。当比较单一类型白细胞(尤其是嗜中性粒细胞和淋巴细胞)的鉴定时,自动化方法比DM96V或手动方法更精确。但是,自动化方法的精度仅对单核细胞而言是公平的,而Advia和Sysmex未能鉴定嗜碱性粒细胞。 Advia报告的单核细胞和嗜酸性粒细胞比其他方法少。与Sysmex,Advia和DM96V相比,通过手动方法鉴定出的淋巴细胞明显更少。 DM96V偶尔会出现相同嗜中性粒细胞的重复图像。结论:CellaVision DM96V是用于促进犬类差异白细胞计数的令人满意的系统。 DM96V差异计数与手动计数相比,与自动计数更为相似,后者更精确,但在检测某些类型的白细胞时存在错误和遗漏。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号