首页> 外文期刊>Veterinary and Comparative Orthopaedics and Traumatology >Evaluation of compression generated by self compressing Orthofix bone pins and lag screws in simulated lateral humeral condylar fractures.
【24h】

Evaluation of compression generated by self compressing Orthofix bone pins and lag screws in simulated lateral humeral condylar fractures.

机译:通过自压缩Orthofix骨钉和方头螺钉在模拟的肱骨外侧lateral突骨折中产生的压力进行评估。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A simulated lateral humeral condylar fracture was created in each of the 52 humeri collected from 26 dogs. One humerus from each pair was stabilized with a 2.0 mm cortical bone screw which was inserted in lag fashion. The other humerus from each pair was stabilized with a 2.2 mm threaded diameter Orthofix pin inserted across the condyle. Prior to each repair, an antirotational K-wire was placed and then the Pressurex Sensitive film was inserted in the osteotomy site in order to determine the compressive pressure (MPa), compressive force (KN), and area of compression (cm2) achieved during fixation. The maximum insertional torque achieved before stripping was measured for each implant. The mean compression generated by insertion of a 2.0 mm lag screw was 20.36+or-1.51 MPa compared to 18.88+or-1.76 MPa generated by a 2.2 mm Orthofix pin (p<0.003). The mean area of compression generated by insertion of a 2.0 mm lag screw was 2.39+or-1.29 cm2, compared to 1.16+or-0.84 cm2 generated by insertion of a 2.2 mm Orthofix pin (p<0.0001). The mean compressive force (compression x area compressed) generated by insertion of a 2.0 mm lag screw was 4.96+or-2.90 Kn, compared to 2.20+or-1.65 Kn generated by insertion of a 2.2 mm Orthofix pin (p<0.0001). The mean insertion torque to failure for the lag screws was 0.49+or-0.07 NM, compared to 0.91 NM+or-0.18 NM generated by the Orthofix pins (P<0.0001). Both repair methods are likely to be acceptable for the repair of similar fractures in small breed dogs.
机译:在从26只狗收集的52个肱骨中,每个人都产生了一个模拟的肱骨lateral外侧骨折。每对中的一个肱骨用2.0 mm皮质骨螺钉稳定放置,该螺钉以滞后方式插入。每对中的另一只肱骨用一个直径为2.2 mm的Orthofix销钉固定在across骨上,以使其稳定。每次修复之前,先放置抗旋转的K线,然后将Pressurex敏感膜插入截骨部位,以确定在此过程中达到的压缩压力(MPa),压缩力(KN)和压缩面积(cm2)固定。测量每个植入物在剥离之前获得的最大插入扭矩。插入2.0毫米方头螺钉产生的平均压缩力为20.36 +或-1.51 MPa,而2.2毫米Orthofix销钉产生的平均压缩力为18.88 +或1.76 MPa(p <0.003)。插入2.0毫米方头螺钉产生的平均压缩面积为2.39 +或-1.29 cm2,而插入2.2 mm Orthofix销所产生的平均压缩面积为1.16 +或-0.84 cm2(p <0.0001)。插入2.0毫米方头螺钉产生的平均压缩力(压缩力x压缩面积)为4.96 +或2.90 Kn,而插入2.2毫米Orthofix销产生的平均压缩力为2.20 +或1.65 Kn(p <0.0001)。方头螺钉的平均失效插入扭矩为0.49+或-0.07 NM,而Orthofix销产生的平均插入扭矩为0.91 NM +或-0.18 NM(P <0.0001)。两种修复方法对于小型犬的类似骨折的修复都是可接受的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号