A method to determine the absolute harmonic content of an X-ray beam using attenuation measurements

机译:一种使用衰减测量确定X射线束的绝对谐波含量的方法

获取原文
获取原文并翻译 | 示例
       

摘要

We present a new method for determining the absolute harmonic content of an X-ray beam. The technique is applied todetermine the harmonic content of a synchrotron beam to high-accuracy by measuring the X-ray attenuation of a large numberof aluminium foils with thicknesses varying over several orders of magnitude. Earlier methods always determined relativequantities such as the effective harmonic content, which are dependant on experimental geometry and not transferable betweendetectors. We use a more fundamental and useful parameter: the harmonic-photon percentage.
机译:我们提出了一种确定X射线束的绝对谐波含量的新方法。该技术通过测量厚度在几个数量级上变化的大量铝箔的X射线衰减来确定高精度的同步加速器光束的谐波含量。早期的方法总是确定相对数量,例如有效谐波含量,这取决于实验几何形状,并且不能在检测器之间转移。我们使用一个更基本和有用的参数:谐波光子百分比。