...
首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Extended storage of buffy coat platelet concentrates in plasma or a platelet additive solution
【24h】

Extended storage of buffy coat platelet concentrates in plasma or a platelet additive solution

机译:血沉棕黄层血小板浓缩液在血浆或血小板添加剂溶液中的扩展存储

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: Platelet (PLT) concentrates (PCs) prepared from whole blood in the United States are made using the PLT-rich plasma method. The PCs must be made within 8 hours of blood collection and stored for only 5 days. In Europe and Canada, PCs are made using the buffy coat (BC) method from whole blood held overnight at 22°C and storage times may be up to 7 days. Our studies were designed to determine how long BC PLTs can be stored in plasma or Plasmalyte while meeting the FDA's poststorage viability criteria. STUDY DESIGN AND METHODS: Normal subjects donated whole blood that was stored at 22°C for 22 ± 2 hours before preparation of BC PLTs. PLTs were stored for 5 to 8 days in either plasma or Plasmalyte concentrations of 65 or 80%. Radiolabeled autologous stored versus fresh PLT recoveries and survivals were assessed as well as poststorage in vitro assays. RESULTS: BC PLTs stored in either plasma or 65% Plasmalyte met FDA poststorage PLT recovery criteria for 7 days but survivals for only 6 days, while storage in 80% Plasmalyte gave very poor results. Both stored PLT recoveries and survivals correlated with the same donor's fresh results, but the correlation was much stronger between recoveries than survivals. In vitro measures of extent of shape change, morphology score, and pH best predicted poststorage PLT recoveries, while annexin V binding best predicted PLT survivals. CONCLUSION: BC PLTs stored in either plasma or 65% Plasmalyte meet FDA's poststorage viability criteria for 6 days.
机译:背景:在美国,从全血中制备的浓缩血小板(PC)是使用富含PLT的血浆方法制备的。 PC必须在采血后8小时内制成,并且只能存放5天。在欧洲和加拿大,使用血沉棕黄层(BC)方法,将全血在22°C下过夜保存,制成PC,并且保存时间最多为7天。我们的研究旨在确定在满足FDA的储藏后生存力标准的情况下,血浆或血浆中BC PLT可以保存多长时间。研究设计和方法:正常受试者捐赠的全血在制备BC PLT之前在22°C下保存22±2小时。 PLT在血浆或血浆中浓度为65%或80%的情况下保存5至8天。评估了放射性标记的自体储存的与新鲜PLT的回收率和存活率,以及储藏后的体外测定。结果:血浆或65%血浆中的BC PLTs符合FDA贮藏后PLT恢复标准,为期7天,但存活期仅为6天,而80%血浆中的BC PLT结果非常差。储存的PLT回收率和存活率均与同一捐赠者的最新结果相关,但回收率之间的相关性要强于存活率。体外测量的形状变化程度,形态评分和pH值最能预测贮藏后PLT的恢复,而膜联蛋白V结合最能预测PLT的存活。结论:血浆或65%血浆中的BC PLTs符合FDA的储藏后生存能力标准达6天。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号