...
首页> 外文期刊>Transfusion: The Journal of the American Association of Blood Banks >Evaluation of a new citrate-acetate-NaCl platelet additive solution for the storage of white cell-reduced platelet concentrates obtained from half-strength CPD pooled buffy coats.
【24h】

Evaluation of a new citrate-acetate-NaCl platelet additive solution for the storage of white cell-reduced platelet concentrates obtained from half-strength CPD pooled buffy coats.

机译:评价一种新的柠檬酸盐-乙酸盐-NaCl血小板添加剂溶液,用于储存从半强度CPD血沉棕黄层获得的减少白细胞的血小板浓缩液。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: A new citrate-acetate-NaCl platelet additive solution, identified as PAS 2, was developed to prepare platelet concentrates (PCs) from pooled 0.5 CPD buffy coats (BCs). STUDY DESIGN AND METHODS: A study was undertaken to evaluate PAS 2 in vitro (n = 8) and in vivo (n = 9) against a commercially available solution (Plasma-Lyte A). In a paired in vitro study, a comparison was made of platelet and white cell concentration; blood gases and bicarbonate; glucose and lactate concentration; total intracellular concentration of adenine nucleotides and beta-thromboglobulin release. RESULTS: A lower platelet yield (p < 0.0001) and a higher beta-thromboglobulin release (p < 0.01) are observed with Plasma-Lyte A. For this reason, half-strength (0.5) CPD was changed to full-strength CPD in the clinical study with Plasma-Lyte A. In a clinical evaluation of nine patients with bone marrow failure, all received PCs with both PAS 2 and Plasma-Lyte A that had a shelf life of at least 4 days. Corrected count increments (CCls) were as follows, on average (95% Cl): the CCl at 1 to 4 hours was 22.4 (95% Cl, 15.2-29.4) for PAS 2 and 24.0 (95% Cl, 16.9-31.2) for Plasma-Lyte A; that at 12 to 24 hours was 11.3 (95% Cl, 4.1-18.4) for PAS 2 and 14.2 (95% Cl, 7.1-21.3) for Plasma-Lyte A; and that at 36 to 48 hours was 4.2 (95% Cl, -3.0-11.3) for PAS 2 and 8.7 (95% Cl, 1.1-16.2) for Plasma-Lyte A. No significant difference between the two solutions was found. CONCLUSIONS: PAS 2 and Plasma-Lyte A make important contributions to platelet transfusion quality improvement and give an excellent CCl even after 4 days of storage.
机译:背景:开发了一种新的柠檬酸盐-乙酸盐-NaCl血小板添加剂溶液,称为PAS 2,用于从合并的0.5 CPD血沉棕黄层(BCs)中制备血小板浓缩物(PCs)。研究设计和方法:进行了一项研究,以针对市售溶液(Plasma-Lyte A)在体外(n = 8)和体内(n = 9)评估PAS 2。在一项配对的体外研究中,比较了血小板和白细胞的浓度。血气和碳酸氢盐;葡萄糖和乳酸浓度;细胞内腺嘌呤核苷酸的总浓度和β-血球蛋白的释放。结果:血浆Lyte A观察到较低的血小板产量(p <0.0001)和较高的β-血球蛋白释放(p <0.01)。因此,在试验组中,半强度(0.5)CPD变为全强度CPD。在对9名骨髓衰竭患者的临床评估中,所有患者均接受了PAS 2和Plasma-Lyte A的PC,它们的保质期至少为4天。校正后的计数增量(CCls)平均如下(95%Cl):1至4小时的CCl对于PAS 2为22.4(95%Cl,15.2-29.4)和24.0(95%Cl,16.9-31.2)对于等离子液A对于PAS 2,在12至24小时的血浆Lyte A分别为11.3(95%Cl,4.1-18.4)和14.2(95%Cl,7.1-21.3);对于PAS 2,在36至48小时时的血浆为4.2(95%Cl,-3.0-11.3),对于血浆L-A细胞,血浆为8.7(95%Cl,1.1-16.2)。两种溶液之间没有发现显着差异。结论:PAS 2和血浆L液对改善血小板输注质量做出了重要贡献,即使在储存4天后仍能提供优异的CCl。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号