The applicability of internal additives for mass scale calibration in time-of-flight secondary ion mass spectrometry (TOF-SIMS) was studied. Relation between the ions selected for mass scale calibration and the relative mass accuracy of the target molecular ions was investigated. Didecyldimethylammonium bromide (dC10DMA(+)Br(-)), dioctadecyldimethylammonium chloride (dC18DMA(+)Cl(-)) and tetradecyltrimethylammonium chloride (C14TMA(+)Cl(-)) as target molecules and octadecyltrimethylammonium chloride (C18TMA(+)Cl(-)) as an internal additive were prepared for positive TOF-SIMS spectra. Tinuvin 770 as a target molecule and sodium hexadecyl sulfate (C16OSO3(-)Na(+)) as an internal additive were used to evaluate negative TOF-SIMS spectra. In the case of dC10DMA(+)Br(-), dC18DMA(+)Cl(-) and Tinuvin 770, the relative mass accuracy of the target molecular ions tends to be improved by mass scale calibration using the molecular ion of the internal additive. The relative mass accuracy of the molecular ion of the target ensured by the mass scale calibration using internal additives was less than approximately +/- 46ppm. In some cases, however, internal additives highly effect on samples and change the sample properties because of coverage of the sample, removing a target molecule or causing matrix effects. It is necessary to evaluate the influence of the internal additive addition before applying internal additives. The detection of target ion peak should be especially confirmed after the addition of the internal additive. When samples are not influenced by internal additive addition, the internal additive method is effective for accurate mass calibration. Copyright (c) 2016 John Wiley & Sons, Ltd.
机译:研究了内部添加剂在飞行时间二次离子质谱(TOF-SIMS)中用于质量标定的适用性。研究了选择用于质量标定的离子与目标分子离子的相对质量精度之间的关系。十二烷基二甲基溴化铵(dC10DMA(+)Br(-)),二十八烷基二甲基氯化铵(dC18DMA(+)Cl(-))和十四烷基三甲基氯化铵(C14TMA(+)Cl(-))作为目标分子和十八烷基三甲基氯化铵(C18TMA(+)Cl (-))作为内部添加剂制备了正TOF-SIMS光谱。 Tinuvin 770作为目标分子和十六烷基硫酸钠(C16OSO3(-)Na(+))作为内部添加剂被用来评估负TOF-SIMS光谱。在dC10DMA(+)Br(-),dC18DMA(+)Cl(-)和Tinuvin 770的情况下,目标分子离子的相对质量精度倾向于通过使用内部添加剂分子离子的质量标定来提高。通过使用内部添加剂的质量标定确保的目标分子离子的相对质量准确度小于大约+/- 46ppm。但是,在某些情况下,内部添加剂会对样品产生很大影响,并且由于样品的覆盖范围,去除目标分子或引起基质效应而改变了样品的性能。在使用内部添加剂之前,有必要评估内部添加剂添加的影响。添加内部添加剂后,应特别确认目标离子峰的检测。当样品不受内部添加剂添加的影响时,内部添加剂方法对于准确的质量校准有效。版权所有(c)2016 John Wiley&Sons,Ltd.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号