首页> 外文期刊>Transactions of the Institutions of Mining and Metallurgy, Section C. Mineral Processing and Extractive Metallurgy >Gas hold-up and solids hold-up in flotation columns: on-line measurement based on electrical conductivity
【24h】

Gas hold-up and solids hold-up in flotation columns: on-line measurement based on electrical conductivity

机译:浮选塔中的气体滞留量和固体滞留量:基于电导率的在线测量

获取原文
获取原文并翻译 | 示例
       

摘要

Electrical conductivity measurements in solid-liquid and solid-liquid-gas dispersions have proven suitable for determination of the volumetric fraction of the phases, or hold-up. A combination of estimation routines was applied to determine the gas hold-up and solids hold-up on line in a flotation column. Gas holdup was determined by using the so-called 'phase separation method' and the standard addition method was used to estimate solids hold-up. Laboratory results validating the techniques and results obtained from applications in industrial flotation columns are presented.
机译:固-液和固-液-气分散体中的电导率测量已证明适用于确定相的体积分数或保持率。应用估算程序的组合来确定浮选塔中的气体滞留率和固体滞留率。通过使用所谓的“相分离法”确定气体滞留率,并使用标准添加法估算固体滞留率。介绍了验证该技术的实验室结果以及从工业浮选塔中获得的结果。