The SimpliRed D-dimer assay is a whole blood agglutination test for the exclusion of pulmonary embolism (PE) and has been advocated as a reliable rapid bedside alternative to more time-consuming quantitative assays. However, widely differing negative predictive values (77-100%) are reported. This study assessed the intra- and interobserver variability as a possible cause for this wide accuracy range and evaluated the accuracy of the SimpliRed test in 81 consecutive patients with clinically suspected PE. Absolute D-dimer concentration was measured using the Tinaquant (Roche Diagnostics GmbH, Mannheim, Germany) assay. Every assay was immediately scored by one observer and then photographed. Photos were randomised and read twice by two other independent observers. The intraobserver reproducibility was good: kappa=0.81 and 0.73. However, we found poor interobserver reproducibility with kappa=0.47. This seems due to the fact that the SimpliRed test proved difficult to interpret in the 0.3-1.3 microg/mL plasma concentration D-dimer range, which contained 32/81 (40%) patients, 8 of whom had PE. Using pulmonary angiograms and ventilation perfusion lung scans with a concurrent spiral computed tomography scan as a gold standard (25 patients had PE), SimpliRed's accuracy to exclude PE was moderate, with negative predictive values of 0.78 and 0.84. In particular, the two observers scored the SimpliRed test as normal in 12 of 25 and 5 of 25 patients with proven PE. We conclude that SimpliRed is strongly observer-dependent. This explains the varying sensitivities for the detection of venous thromboembolism as reported in previous studies.
机译:SimpliRed D-二聚体测定是一种全血凝集试验,用于排除肺栓塞(PE),并已被提倡为一种可靠的快速床旁替代品,取代了耗时的定量测定。但是,据报道,阴性预测值差异很大(77-100%)。这项研究评估了观察者内和观察者间的变异性是造成此较大准确性范围的可能原因,并评估了SimpliRed测试在81例临床怀疑为PE的连续患者中的准确性。使用Tinaquant(Roche Diagnostics GmbH,曼海姆,德国)测定法测量D-二聚体的绝对浓度。一位观察员立即对每项测定进行评分,然后拍照。照片被随机化,并由另外两个独立的观察者阅读两次。观察者内的再现性良好:κ= 0.81和0.73。但是,我们发现kappa = 0.47时观察者之间的可重复性很差。这似乎是由于事实证明SimpliRed测试难以在0.3-1.3 microg / mL血浆浓度D-二聚体范围内进行解释,其中包含32/81(40%)患者,其中8人患有PE。使用肺血管造影和通气灌注肺扫描,同时进行螺旋计算机断层扫描作为金标准(25例患有PE),SimpliRed排除PE的准确性中等,阴性预测值为0.78和0.84。尤其是,两位观察者对25例确诊为PE的患者中的12例和25例中的5例的SimpliRed测试评分为正常。我们得出的结论是SimpliRed强烈依赖于观察者。这解释了先前研究中报道的检测静脉血栓栓塞的不同敏感性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号