D-dimer is an indicator for in vivo fibrin formation, reflecting the formation of fibrin crosslinked by factor XIIIa. D-dimer assays are frequently used in emergency situations, such as diagnosis of venous thrombosis and pulmonary embolism, or disseminated intravascular coagulation. In these conditions, short sample turnaround times are essential. The PATHFAST D-dimer assay allows rapid quantitative measurement of D-dimer in plasma and whole blood. The study shows an excellent correlation between whole blood and plasma measurement of D-dimer both in the high range, as well as in the normal range. Intra-assay and inter-assay coefficients of variation (CV) were below 10%. The upper limit of normal (ULN = mean value measured in 100 samples from healthy blood donors + 2 x S.D.) was approximately 1 microg/ml FEU, using the assay-specific calibration. The maximal value measured in 20 replicates of calibrator 1 containing no D-dimer antigen was 0.00052 microg/ml FEU, and this 10-fold lower than the declared detection limit of 0.005 microg/ml FEU. In conclusion, the PATHFAST D-dimer assay is the first automated fully quantitative D-dimer assay, which can use plasma and whole blood as sample materials in parallel.
机译:D-二聚体是体内纤维蛋白形成的指示剂,反映了通过因子XIIIa交联的纤维蛋白的形成。 D-二聚体测定法经常用于紧急情况,例如诊断静脉血栓形成和肺栓塞或弥散性血管内凝血。在这些条件下,必须缩短样品周转时间。 PATHFAST D-二聚体测定可以快速定量测量血浆和全血中的D-二聚体。该研究表明,在高范围和正常范围内,全血与D-二聚体的血浆测量值之间都具有极好的相关性。批内和批间变异系数(CV)低于10%。使用分析特异性校准,正常值的上限(ULN =从健康献血者中抽取的100个样品中测得的平均值+ 2 x S.D.)约为1微克/毫升FEU。在不包含D-二聚体抗原的校准品1的20个重复样品中测得的最大值为0.00052微克/毫升FEU,比声明的检测限度0.005微克/毫升FEU低了10倍。总之,PATHFAST D-二聚体测定是第一个自动化的完全定量D-二聚体测定,可以并行使用血浆和全血作为样品材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号