...
首页> 外文期刊>The Veterinary Journal >Diagnostic utility of a direct immunofluorescence test to detect feline coronavirus antigen in macrophages in effusive feline infectious peritonitis.
【24h】

Diagnostic utility of a direct immunofluorescence test to detect feline coronavirus antigen in macrophages in effusive feline infectious peritonitis.

机译:直接免疫荧光测试的诊断实用程序,用于检测散发性猫传染性腹膜炎巨噬细胞中的猫冠状病毒抗原。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The antemortem diagnosis of feline infectious peritonitis (FIP) remains challenging in clinical practice, since current testing methods have suboptimal diagnostic accuracy. Immunohistochemical testing of biopsy specimens and postmortem examination are the standard diagnostic methods, although direct immunofluorescence (DIF) testing to detect feline coronavirus in macrophages in effusion specimens has been reported to have 100% specificity and has been recommended as an antemortem confirmatory test. The aim of this study was to compare the results of DIF testing in antemortem feline effusions with postmortem results using field samples. Effusion specimens were collected antemortem from 17 cats and tested by DIF, followed by postmortem examination. Histopathological examination of specimens collected at postmortem confirmed FIP in 10/17 cases and ruled out FIP out in 7/17 cases. Antemortem DIF testing was positive in all 10 cases confirmed as FIP at postmortem examination. In the seven cats where FIP was ruled out at postmortem examination, DIF was negative in five cases and positive in the remaining two cases. The calculated sensitivity of DIF testing was 100% and the specificity was 71.4%. Duplicate effusion specimens from eight cats that were initially DIF positive were stored refrigerated (4 degrees C) or at room temperature (22-25 degrees C) and subjected to serial DIF testing to determine the duration of positive results. DIF-positive specimens stored at both temperatures retained their positive status for at least 2 days.
机译:猫传染性腹膜炎(FIP)的死前诊断在临床实践中仍然具有挑战性,因为当前的测试方法的诊断准确性欠佳。活检标本的免疫组织化学检测和死后检查是标准的诊断方法,尽管据报道直接免疫荧光(DIF)检测可在积液标本中检测巨噬细胞中猫冠状病毒,但具有100%的特异性,因此建议将其作为死前确认试验。这项研究的目的是比较使用现场样本进行的死前猫积液中DIF测试的结果与死后结果。从17只猫的死前收集渗出样本,并通过DIF进行测试,然后进行死后检查。死后采集的标本的组织病理学检查证实FIP占10/17例,排除FIP占7/17例。在死后检查中被确认为FIP的所有10例,死前DIF检测均为阳性。在死后检查中排除FIP的7只猫中,DIF在5例中为阴性,在其余2例中为阳性。 DIF检测的计算灵敏度为100%,特异性为71.4%。将八只最初DIF呈阳性的猫的双份积液样本冷藏(4摄氏度)或在室温(22-25摄氏度)下保存,并进行连续DIF测试以确定阳性结果的持续时间。在两种温度下保存的DIF阳性样本均保持其阳性状态至少2天。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号