This study aimed to evaluate the use of extradural pressure (EDP) waves to confirm extradural needle placement in clinical practice. Lumbosacral extradural anaesthesia was performed in 98 dogs, of which 85 were included for statistical analysis. The extradural space was identified using conventional methods and, after testing lack of resistance to injection of saline, a pressure transducer was connected to the needle. EDP and the occurrence of pressure waves were recorded before and following injection of local anaesthetic. Successful administration of the drug was confirmed by clinical assessment. Extradural anaesthesia was successful in 88% of the dogs. Pressure waves were present in 89% of the animals with successful extradural puncture, but in 35% of dogs the waves occurred following extradural injection but not before. In 11% of dogs no EDP waves were observed. EDP prior to administration of the local anaesthetic was 0.4+or-1.0 kPa but following the injection values were significantly higher (4.7+or-2.9 kPa) and there was no difference between pressures following successful and unsuccessful punctures. It was concluded that EDP waves can be used to confirm correct needle placement in dogs in clinical practice and measurement is most reliable following extradural injection.Digital Object Identifier http://dx.doi.org/10.1016/j.tvjl.2009.06.006
机译:这项研究旨在评估硬膜外压力(EDP)波在临床实践中确认硬膜外针头放置的使用。腰ac硬膜外麻醉是在98只狗中进行的,其中有85只用于统计分析。使用常规方法识别硬膜外腔,并在测试对盐水注射的抵抗力不足后,将压力传感器连接至针头。在注射局部麻醉剂之前和之后,记录EDP和压力波的发生。通过临床评估证实药物的成功给药。硬膜外麻醉在88%的狗中成功。成功完成硬膜外穿刺的动物中存在压力波,但在35%的狗中,压力波是在硬膜外注射后发生的,而不是在之前。在11%的狗中未观察到EDP波。局部麻醉前的EDP为0.4+或-1.0 kPa,但是注射后的EDP值显着更高(4.7+或-2.9 kPa),成功和不成功穿刺后的压力之间没有差异。结论是EDP波可用于在临床实践中确认狗中正确的针头位置,并且在硬膜外注射后测量是最可靠的。数字对象标识符http://dx.doi.org/10.1016/j.tvjl.2009.06.006

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号