Inherent Strength of the osteo-WEDGE (TM) Bone Plate Locking System for Arthrodesis of the First Metatarsocuneiform Joint: A Biomechanical Study

机译:骨-WEDGE(TM)骨板锁定系统的固有强度,用于第一个Meta骨形关节的关节固定术:一项生物力学研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

First metatarsocuneiform joint arthrodesis with a locking bone plate and screw system has been effectively used to correct metatarsus primus varus and instability of the first ray. The goal of the present cadaveric biomechanical study was to quantify and compare the inherent strength of the first metatarsocuneiform joint and surrounding bones fixated with the osteo-WEDGE (TM) bone plate locking system (OW) with that of intact specimens. Fourteen fresh-frozen adult human cadaveric foot specimens consisting of the first metatarsal and medial cuneiform bones with intact joint capsules and ligaments were used. The OW was implanted in 7 of these specimens at the first metatarsal cuneiform joint (MCJ), and the remaining 7 specimens were left intact. Each of the specimens was then subjected to axial force to simulate dorsiflexion of the first metatarsal using a cantilever bending test setup. Load was applied on the plantar aspect of the first metatarsal head until failure of the construct. The mean load and bending moment on the first MCJ at failure for the implanted specimens were 119.98 +/- 56.76 N and 5.57 +/- 2.71 Nm, respectively. For the intact specimens, the mean load and bending moment on the first MCJ at failure were 107.93 +/- 60.90 N and 6.07 +/- 3.18 Nm, respectively. None of the specimens showed catastrophic failure within the physiologic loading limits. These results imply that the mechanical strength of the OW is comparable to that of intact specimens. Thus, the first MCJ and surrounding bones fixated with an OW should be able to effectively withstand the vertical ground reaction forces the same as intact specimens. (C) 2016 by the American College of Foot and Ankle Surgeons. All rights reserved.
机译:具有锁定骨板和螺钉系统的第一meta骨关节状关节固定术已被有效地用于矫正meta骨原始内翻和第一射线的不稳定性。目前的尸体生物力学研究的目的是量化和比较用骨WEDGE(TM)骨板锁定系统(OW)固定的第一个meta骨形关节和周围骨骼的固有强度与完整样本的内在强度。使用十四个新鲜冷冻的成人尸体足标本,该标本由第一the骨和内侧楔形骨以及完整的关节囊和韧带组成。 OW被植入第一个meta骨楔形关节(MCJ)的7个标本中,其余7个标本完好无损。然后,使用悬臂弯曲测试装置对每个样本施加轴向力,以模拟第一meta骨的背屈。在第一个meta骨头的足底部分施加载荷,直到构造失败。植入的样品在第一MCJ断裂时的平均载荷和弯矩分别为119.98 +/- 56.76 N和5.57 +/- 2.71 Nm。对于完好无损的试样,第一个MCJ断裂时的平均载荷和弯矩分别为107.93 +/- 60.90 N和6.07 +/- 3.18 Nm。在生理负荷极限内,没有一个标本显示出灾难性的破坏。这些结果表明,OW的机械强度与完整样本的机械强度相当。因此,第一个MCJ和用OW固定的周围骨骼应该能够有效地承受与完整样本相同的垂直地面反作用力。 (C)2016年美国足踝外科医师学院。版权所有。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号