首页> 外文期刊>The American Journal of Cardiology >Safety of Slender 5Fr Transradial Approach for Carotid Artery Stenting With a Novel Nitinol Double-Layer Micromesh Stent
【24h】

Safety of Slender 5Fr Transradial Approach for Carotid Artery Stenting With a Novel Nitinol Double-Layer Micromesh Stent

机译:细长的5Fr Micro动脉入路用于新型镍钛诺双层微网支架置入颈动脉支架的安全性

获取原文
获取原文并翻译 | 示例

摘要

We aimed to evaluate the feasibility and safety of performing percutaneous carotid stent implantation with a newly designed double-layer stent using transradial slender 5Fr techniques. We recruited 10 consecutive patients who underwent percutaneous carotid stenting using nitinol double-layer micromesh (Roadsaver) stents. Mean age of patients was 66 years. Seven patients had >= 2 high-risk criteria according to SAPPHIRE classification. Indication was neurologic symptoms in 7 and severe lesion without symptoms in 3 cases. Type 2 aortic arch was present in 8 patients and type 1 in 2 patients. Access was right radial artery in 9 cases and right ulnar artery in 1 case. Right carotid artery was stented in 4 cases and left carotid artery in 6 cases. Embolic protection device (EPD) was used in 6 cases. Nine stents were successfully delivered using 5Fr destination sheath (n = 7) or shuttle sheath (n = 2), and 1 was implanted using Mo-Ma 8Fr proximal EPD. Procedural success was obtained in all cases with only 1 case of temporary vasospasm due to distal EPD. Total procedural time was 21 minutes (13 to 30 minutes) with filter time of 5 +/- 1 minutes. Fluoroscopy time was 8 minutes (5 to 12 minutes) and contrast volume was 150 ml (100 to 200 ml). Hospital stay was 1 +/- 1 day with 4 patients discharged on the same day of the procedure. Using right transradial approach and slender 5Fr techniques, this new double-layer micromesh stent can be implanted in left and right carotid arteries with promising results. (C) 2015 Elsevier Inc. All rights reserved.
机译:我们的目的是评估使用经radi骨细长5Fr技术使用新设计的双层支架进行经皮颈动脉支架植入术的可行性和安全性。我们招募了10名连续的患者,这些患者使用镍钛合金双层微网(Roadsaver)支架进行了经皮颈动脉支架置入术。患者的平均年龄为66岁。根据SAPPHIRE分类,七名患者具有> = 2个高危标准。适应症为神经系统症状7例,重度病变无症状3例。 8例中有2型主动脉弓,2例中有1型主动脉弓。通路为右right动脉9例,右尺动脉1例。右颈动脉置入支架4例,左颈动脉置入支架6例。 6例使用了栓塞保护装置(EPD)。使用5Fr目的地鞘管(n = 7)或穿梭鞘管(n = 2)成功递送了9个支架,并使用Mo-Ma 8Fr近端EPD植入了1个支架。在所有病例中,只有1例因远端EPD引起的暂时性血管痉挛获得了手术成功。总程序时间为21分钟(13至30分钟),过滤时间为5 +/- 1分钟。荧光检查时间为8分钟(5至12分钟),造影剂体积为150 ml(100至200 ml)。住院时间为1 +/- 1天,当天有4名患者出院。使用右trans骨入路方法和细长的5Fr技术,这种新型双层微网状支架可以植入左颈动脉和右颈动脉中,并获得可喜的结果。 (C)2015 Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号