Measurements of the anisotropy of ultrasonic attenuation in freshly excised myocardium

机译:新鲜切除心肌的超声衰减各向异性测量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Echocardiography requires imaging of the heart with sound propagating at varying angles relative to the predominant direction of the myofibers. The degree of anisotropy of attenuation can significantly influence ultrasonic imaging and tissue characterization measurements in vivo. This study quantifies the anisotropy of attenuation of freshly excised myocardium at frequencies typical of echocardiographic imaging. Results show a significantly larger anisotropy than previously reported in specimens of locally unidirectional myofibers. Through-transmission radio frequency-based measurements were performed on specimens from 12 ovine and 12 bovine hearts. Although ovine hearts are closer in size to human, the larger size of bovine hearts offers the potential for specimens in which myofibers are more nearly unidirectionally aligned. The attenuation coefficient increased approximately linearly with frequency. The mean slope of attenuation with frequency was 3-4 times larger for propagation parallel than for perpendicular to the myofibers. At perpendicular insonification, slopes between ovine and bovine myocardium were approximately equal. However, attenuation in bovine specimens was larger for angles approaching parallel. The difference in results for parallel appears consistent with what might be expected from increased myofiber curvature associated with smaller lamb hearts. Quantitative knowledge of anisotropy of attenuation may be useful in understanding mechanisms underlying the interaction of ultrasound with myocardium. (c) 2006 Acoustical Society of America.
机译:超声心动图要求以相对于肌纤维主要方向以不同角度传播的声音对心脏成像。衰减的各向异性程度可以显着影响体内的超声成像和组织表征测量。这项研究量化了超声心动图成像的典型频率下新鲜切除的心肌衰减的各向异性。结果显示,各向异性比以前在局部单向肌纤维样本中报告的要大得多。对来自12个绵羊心脏和12个牛心脏的样本进行了基于透射射频的测量。尽管绵羊心脏的尺寸更接近人类,但较大尺寸的牛心脏为肌纤维几乎单向排列的标本提供了潜力。衰减系数随频率近似线性增加。平行传播的衰减随频率的平均斜率是垂直于肌纤维传播的3-4倍。在垂直声波作用下,绵羊和牛心肌之间的斜率大致相等。但是,当牛角接近平行时,牛标本的衰减较大。平行结果的差异似乎与小羊羔心脏相关的肌纤维曲率增加所预期的一致。衰减各向异性的定量知识可能有助于理解超声与心肌相互作用的机理。 (c)2006年美国声学学会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号