Effective measurement of knee alignment using AP knee radiographs.

机译:使用AP膝部X射线照片可有效测量膝部对中。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

The gold standard for measuring knee alignment is mechanical axis determined using full-limb radiographs (FLR). Measurement of joint alignment using antero-posterior (AP) knee radiographs is more accessible, economical and involves less radiation exposure to the patient compared with using full-limb radiographs. The aim of this study was to compare and assess the reproducibility of knee joint axial alignment on full-limb radiographs and conventional AP knee radiographs. Knee alignment was measured in 40 subjects (80 knees) from the TwinsUK registry. Measurement of mechanical knee alignment was from FLR, and anatomic knee alignment from weight-bearing AP knee radiographs. Reproducibility was assessed by intra-class correlation coefficients and kappa statistics. Reproducibility of knee alignment for both methods was good, with intra-observer ICC's of 0.99 for both FLR and AP radiographs. The mean alignment angle on FLR was 178.9 degrees (SD 2.1, range 173-183 degrees ), and 179.0 degrees (SD 2.1, range 173-185 degrees ) on AP films. 58.8% of knees on FLR and 66.3% on AP films were of varus alignment. Good correlations were seen between results for FLR and AP radiographs, with ICC ranging from 0.87-0.92 for left and right knees, and kappa statistics of 0.65-0.74. Standard AP knee radiographs can be used to measure knee alignment with good reproducibility, and provide comparable results to those obtained from FLR. This will facilitate measurement of knee alignment in existing cohort studies to assess malalignment as a risk factor of incident OA, and in clinical practice.
机译:测量膝盖对齐的黄金标准是使用全肢X射线照片(FLR)确定的机械轴。与使用全肢X射线照片相比,使用前后(AP)膝部X射线照片测量关节对准更容易,更经济并且对患者的辐射照射更少。这项研究的目的是比较和评估全肢X光片和常规AP膝部X光片上膝关节轴向对准的可重复性。在TwinsUK注册表中,对40名受试者(80膝)进行了膝关节定位测量。机械膝关节定位的测量来自FLR,解剖学膝关节定位的测量来自承重AP膝关节X光片。通过组内相关系数和κ统计评估可重复性。两种方法的膝盖对准的重现性都很好,FLR和AP射线照相的观察者内部ICC均为0.99。 FLR的平均对准角在AP膜上为178.9度(SD 2.1,范围173-183度),在179.0度(SD 2.1,范围173-185度)上。 FLR膝关节的58.8%和AP膜膝关节的66.3%为内翻对准。 FLR和AP射线照片的结果之间具有良好的相关性,左膝和右膝的ICC范围为0.87-0.92,kappa统计值为0.65-0.74。标准的AP膝部X射线照片可用于以良好的可重复性测量膝盖的对中,并提供与从FLR获得的结果可比的结果。这将有助于在现有的队列研究中评估膝盖的不正直性,以评估将不正直性作为发生OA的危险因素,并在临床实践中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号