首页> 外文期刊>The Journal of Thoracic and Cardiovascular Surgery >Prosthetic aortic valve-pexy: Stitch closure of the aortic valve in a patient with a ventricular assist device
【24h】

Prosthetic aortic valve-pexy: Stitch closure of the aortic valve in a patient with a ventricular assist device

机译:人工主动脉瓣狭窄:使用心室辅助装置缝合患者的主动脉瓣

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Intermittent opening of the mechanical aortic valve after placement of a ventricular assist device (VAD) can lead to an increased risk of thromboembolism. It has been recommended to close the aorta with a patch or replace it with a bio-prosthesis.1'2 Both these methods, however, increase the ischemic time. A single-stitch method to close the mechanical aortic valve has been described3; however, placement of the suture as illustrated in the article is technically very difficult. We therefore describe our modification as used in a patient with a mechanical aortic valve undergoing VAD placement and include intraoperative photographs and an illustration.
机译:放置心室辅助设备(VAD)后,机械主动脉瓣的间歇性打开会导致血栓栓塞的风险增加。建议使用贴片封闭主动脉或用生物假体代替主动脉。1'2然而,这两种方法都增加了缺血时间。已经描述了一种单针方法来关闭机械主动脉瓣3。然而,如本文所述,缝合线的放置在技术上非常困难。因此,我们描述了在接受VAD放置的主动脉机械瓣患者中使用的改良方法,并包括术中照片和插图。