INTRODUCTION: In 2008 Coloplast Corporation modified their Titan inflatable penile prosthesis (IPP) with a new One-Touch Release (OTR) pump, in an attempt to facilitate device deflation. There is currently little published data concerning this new pump. AIM: The aim of this pilot study was to assess initial patient and physician experience with the Titan OTR pump. METHODS: Retrospective chart review was used to assess the functionality and surgeon experience with 100 consecutive patients implanted with a Titan OTR pump, compared with 100 prior consecutive patients implanted with a Titan Genesis pump. MAIN OUTCOME MEASURES: The ease of implantation of the OTR pump, the number of required postoperative inflate/deflate teaching visits, and OTR pump functionality were assessed and compared with that of the prior Genesis pump. RESULTS: The mean length of follow-up in the Genesis group (N = 100) was 20.8 months, and mean length of follow-up in the OTR group (N = 100) was 8.4 months. There was one device infection in each group. The average number of postoperative teaching sessions needed to teach the patient how to operate the device was 1.87 in the Genesis group, and 1.19 in the OTR group (P < 0.001). The range of teaching visits was 1-5 in the Genesis group, and 1-3 in the OTR group (P < 0.001). No pump malfunctions were seen in either group. Subjectively, the OTR pump was just as easy to implant as the Genesis pump. In addition, the OTR pump was subjectively easier for the surgeon and the patient to deflate, and just as easy to inflate, compared with the Genesis pump. CONCLUSIONS: This pilot study revealed that the OTR pump functioned as specified by the manufacturer. With short-term follow-up, no pump malfunctions were detected. The OTR pump was associated with a statistically significant reduction in the number of postoperative teaching sessions required for the patient to properly operate the device. It was subjectively just as easy to implant and inflate, and easier to deflate, compared with the Genesis pump.
机译:简介:2008年,Coloplast公司用一种新型的一触式释放(OTR)泵对他们的Titan充气式阴茎假体(IPP)进行了改进,以试图使设备放气。当前很少有关于这种新泵的公开数据。目的:这项初步研究的目的是评估Titan OTR泵的初步患者和医生经验。方法:回顾性图表回顾用于评估100例连续植入Titan OTR泵的患者的功能和外科医生的经验,而100例先前连续植入Titan Genesis泵的患者。主要观察指标:评估OTR泵的植入简易性,术后所需的充气/放气教学访问次数以及OTR泵功能,并将其与以前的Genesis泵进行比较。结果:Genesis组的平均随访时间为20.8个月,OTR组的平均随访时间为8.4个月(N = 100)。每组中只有一种设备感染。在Genesis组中,教给患者如何操作该设备的术后平均教学次数为1.87,而在OTR组中,则为1.19(P <0.001)。创世纪组的教学探访范围为1-5,OTR组为1-3(P <0.001)。两组均未发现泵故障。从主观上讲,OTR泵与Genesis泵一样容易植入。此外,与Genesis泵相比,OTR泵在主观上更容易使外科医生和患者放气,并且同样容易充气。结论:该初步研究表明,OTR泵的功能符合制造商规定。经过短期跟踪,未发现任何泵故障。 OTR泵在统计学上显着减少了患者正确操作设备所需的术后教学时间。与Genesis泵相比,从主观上讲,它易于植入和充气,也更容易放气。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号