首页> 外文期刊>The Journal of Urology >Tissue reactions of 5 sling materials and tissue material detachment strength of 4 synthetic mesh materials in a rabbit model.
【24h】

Tissue reactions of 5 sling materials and tissue material detachment strength of 4 synthetic mesh materials in a rabbit model.

机译:在兔子模型中,5种吊带材料的组织反应和4种合成网状材料的组织材料分离强度。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: We evaluated tissue reactions to 5 sling materials used in tension-free vaginal tape (TVT), intravaginal slingplasty (IVS), polypropylene mesh hernia repair, the suprapubic approach to suburethral polypropylene tape (SPARC) and cadaveric fascia lata procedures. We also compared the mesh-to-tissue attachment strength of 4 sling mesh materials (TVT, IVS, surgical polypropylene mesh and SPARC) at on days 2, 7, 15 and 30 after implantation. MATERIALS AND METHODS: A total of 20 female New Zealand White rabbits were randomized to group 1-2 days, group 2-7 days, group 3-15 days and group 4-30 days. After the rabbits were anesthetized an 8 cm midline incision was made for rectus muscle access, and 0.5 x 1 cm pieces of TVT, IVS, SPARC, surgical polypropylene mesh and cadaveric fascia lata were sewn to the rectus muscle with direct contact. At the same time 4 subfascial tunnels in the medial surface of the upper extremities were prepared, and 1.0 x 0.5 cm strips of TVT, IVS, SPARC and polypropylene meshwere implanted in each tunnel. On days 2, 7, 15 and 30 after implantation mechanical testing was performed to define tissue detachment strength. The strips of 5 sling materials were then harvested with the surrounding tissue. Specimens were studied by light microscopy. RESULTS: Mean detachment strength, that is the minimum weight needed to move the mesh, of the synthetic meshes from days 2 to 30 were 291.6 to 2,390.0 gm for TVT, 178.4 to 2,160.0 gm for SPARC, 188.4 to 1,850.0 gm for hernia mesh and 92.8 to 1,510.0 gm for IVS (at all data points TVT vs IVS p < 0.05). Light microscopy revealed a quite uniform tissue reaction with a sign of marked acute inflammation in and around the mesh fibers on days 2 and 7 after implantation. All meshes showed stable fibrosis and muscle infiltration on day 30. CONCLUSIONS: All 5 synthetic sling materials produce similar tissue reactions beginning soon after implantation. Cadaveric fascia lata persisted in tissue with remarkable perifascial fibrosis at day 30. When comparingthe 4 polypropylene mesh materials; the attachment capacity of TVT was superior and that of IVS was the least of the 4. TVT was statistically better than IVS at all data points. SPARC and hernia mesh provided results similar to those of TVT.
机译:目的:我们评估了对无张力阴道带(TVT),阴道内单带成形术(IVS),聚丙烯网疝修补,耻骨上经尿道下聚丙烯带(SPARC)和尸体筋膜Lata手术使用的5种吊带材料的组织反应。我们还比较了植入后第2、7、15和30天的4种吊带网材料(TVT,IVS,外科聚丙烯网和SPARC)的网对组织附着强度。材料与方法:将20只雌性新西兰白兔随机分为1-2天,2-7天,3-15天和4-30天。麻醉兔后,在中线切一个8厘米的切口用于直肌,并直接接触将0.5 x 1厘米的TVT,IVS,SPARC,外科聚丙烯网和尸体筋膜缝合到直肌上。同时,在上肢内侧表面准备了4条筋膜下隧道,并在每条隧道中植入1.0 x 0.5 cm TVT,IVS,SPARC和聚丙烯网状带。植入后第2、7、15和30天进行机械测试以定义组织分离强度。然后将5个吊索材料带与周围的组织一起收获。通过光学显微镜研究标本。结果:从第2天到第30天,合成网格的平均分离强度(移动网格所需的最小重量)分别为:TVT为291.6至2,390.0 gm,SPARC为178.4至2,160.0 gm,疝气网为188.4至1,850.0 gm和92.8 IVS为1,510.0 gm(在所有数据点TVT与IVS p <0.05)。光学显微镜检查显示,植入后第2天和第7天,网状纤维内部及其周围有明显的急性炎症迹象,组织反应非常均匀。在第30天,所有网片均显示出稳定的纤维化和肌肉浸润。结论:所有5种合成吊索材料在植入后不久即开始产生相似的组织反应。尸体筋膜筋膜在第30天时在组织中持续存在着明显的筋膜周围纤维化。在所有数据点上,TVT的附着能力均优于IVS,IVS的附着能力最低。4。TVT在统计学上优于IVS。 SPARC和疝气网提供的结果与TVT相似。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号