首页> 外文期刊>The Journal of Urology >Ordinary glass spheres as an alternative injectable material for endoscopic correction of vesicoureteral reflux.
【24h】

Ordinary glass spheres as an alternative injectable material for endoscopic correction of vesicoureteral reflux.

机译:普通玻璃球作为内窥镜检查膀胱输尿管反流的替代注射材料。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: Although they are therapeutically effective, injectable materials for urinary tract are associated with various disadvantages, precluding their universal acceptance. In this study we investigated glass spheres (GSs) as an alternative injectable substance to correct vesicoureteral reflux (VUR) in an animal model. MATERIALS AND METHODS: We used 150 to 300 micro GSs suspended in agarose gel to form the injection paste. GS paste was injected into the rectus muscle and submucosa of the bladder in 8 adult New Zealand male rabbits. As a control group, vehicle only was injected into 4 rabbits. The rabbits were sacrificed to harvest the bladder, pelvic lymph nodes, kidney, liver, brain, spleen and lung at month 1 and year 1 of injection. A VUR model was then created by unroofing the 2 ureteral orifices of 12 adult sheep. GS paste was injected into the right subureter and vehicle only was injected into the left subureter. Cystourethrographies were performed at month 3 and year 1 of injection. The sheep were sacrificed at cystourethrography to harvest the bladder, lymph nodes, kidney, liver, brain, spleen and lung. RESULTS: At month 3 and year 1 of injection into rabbit tissues nodule formation was stable in position and volume. Histopathological studies of local and distant organs of the rabbit did not show any granuloma formation or migration of GS. GS paste injection corrected VUR in sheep. Re-injection of GS into still refluxing left units corrected VUR. Local and distant organs harvested from sheep did not demonstrate distant migration. CONCLUSIONS: When injected into bladder submucosa and rectus muscle, GS appears to be inert, biocompatible and efficient. Similarly it is effective for correcting VUR in an animal model. We present our data on GS, encouraging further investigation to develop an alternative injectable material for endoscopic VUR correction.
机译:目的:尽管它们是治疗有效的,但用于尿路的可注射材料伴随着各种不利条件,排除了它们的普遍接受性。在这项研究中,我们研究了玻璃球(GSs)作为可替代物质,以纠正动物模型中的膀胱输尿管反流(VUR)。材料与方法:我们将150至300微克GS悬浮在琼脂糖凝胶中以形成注射糊剂。将GS糊剂注射入8只成年新西兰雄兔的直肌和膀胱粘膜下层。作为对照组,仅将媒介物注射到4只兔子中。在注射的第1个月和第1年,处死兔子以收获膀胱,骨盆淋巴结,肾脏,肝脏,大脑,脾脏和肺。然后通过解开12只成年绵羊的2个输尿管口来创建VUR模型。 GS糊剂注入右输尿管,仅溶媒注入左输尿管。在注射的第3个月和第1年进行膀胱尿道造影。在膀胱尿描记术中处死绵羊以收获膀胱,淋巴结,肾脏,肝脏,大脑,脾脏和肺脏。结果:在兔组织注射的第3个月和第1年,结节的位置和体积均稳定。兔子局部和远处器官的组织病理学研究未显示任何肉芽肿形成或GS迁移。 GS糊剂注射纠正了绵羊中的VUR。将GS重新注入仍在回流的左侧装置中可纠正VUR。从绵羊收获的局部和远处器官未显示出远距离迁移。结论:当将GS注射入膀胱粘膜下层和直肌时,它似乎是惰性的,生物相容性和有效的。同样,它对于纠正动物模型中的VUR也很有效。我们提供有关GS的数据,鼓励进一步研究以开发用于内窥镜VUR矫正的替代可注射材料。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号