首页> 外文期刊>The journal of trauma and acute care surgery >Screw- versus plate-fixation strength of acetabular anterior column fractures: a biomechanical study.
【24h】

Screw- versus plate-fixation strength of acetabular anterior column fractures: a biomechanical study.

机译:髋臼前柱骨折的螺钉固定与钢板固定强度:一项生物力学研究。

获取原文
获取原文并翻译 | 示例
           

摘要

The standard for operative treatment of acetabular fractures is open reduction and plate fixation. Recently, screw fixation-only methods through less invasive approaches are reported, but biomechanical data are missing. Questions posed in this study are (1) is the static fixation strength of different screw types equivalent to the standard plate fixation for anterior column fractures of the acetabulum? and (2) does the placement of an additional screw in the infra-acetabular corridor increase the fixation strength independent of the used implant?Three groups of different screws (group II, titanium; group III, stainless steel; and group IV, biodegradable Poly-L-Lactid) were compared with the standard plate fixation (group I) in Synbone pelves with custom-made anterior column fractures. Six pelvises per group were axial loaded with six cycles of 800 N, twice with and without an additional placed infra-acetabular screw.The fixation strength of titanium screws was equivalent to the standard plate fixation. The stainless steel and Poly-L-Lactid screw fixation strengths were equivalent to each other but inferior to the aforementioned. The additional placement of an infra-acetabular screw significantly increased the fracture fixation strength, independent of the used implant.Screw fixation is a promising alternative approach for the stabilization of noncomminuted acetabular fractures of the anterior column with equivalent fixation strength to the standard plate fixation. The additional placement of an infra-acetabular screw significantly increases the fracture fixation independent of the used implant and should be considered for acetabular fractures with separation of both columns.Therapeutic study, level IV.
机译:髋臼骨折的手术治疗标准是切开复位钢板固定。近来,报道了通过较少侵入性方法的仅螺钉固定方法,但是缺少生物力学数据。这项研究提出的问题是(1)不同螺钉类型的静态固定强度是否等同于髋臼前柱骨折的标准钢板固定? (2)在髋臼下廊中放置额外的螺钉是否会增加固定强度,而与使用的植入物无关?三组不同的螺钉(II组,钛; III组,不锈钢; IV组,可生物降解的聚-L-Lactid)与标准板固定(I组)在定制前柱骨折的Synbone骨中进行比较。每组六个骨盆承受800 N的六个循环的轴向载荷,在有或没有额外放置髋臼下螺钉的情况下进行两次,钛螺钉的固定强度与标准钢板固定相同。不锈钢和Poly-L-Lactid螺钉的固定强度彼此相等,但不及上述强度。髋臼下螺钉的额外放置可显着提高骨折固定强度,而与使用的植入物无关。螺钉固定是一种稳定前柱非粉碎性髋臼骨折的有前途的替代方法,其固定强度与标准钢板固定相当。髋臼下螺钉的额外放置可显着增加骨折的固定,而与所用的植入物无关,并且应考虑将髋臼骨折并用两根柱子分开。治疗研究,IV级。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号