首页> 外文期刊>The Journal of Prosthetic Dentistry >Comparison of the retentive properties of six prefabricated post overdenture attachment systems.
【24h】

Comparison of the retentive properties of six prefabricated post overdenture attachment systems.

机译:六个预制的覆盖义齿后附着系统的保持性能的比较。

获取原文
获取原文并翻译 | 示例
       

摘要

STATEMENT OF PROBLEM: There are few research studies concerning prefabricated posts overdenture attachment systems using multiple pull cycles. PURPOSE: This study tested 6 prefabricated post overdenture attachment systems (AccessPost Overdenture, ERA white and ERA grey, Flexi-Overdenture, O-SO and ZAAG) measured to simulate wear over a 2000 pull cycle and compared the in vitro retention, measured (pounds). MATERIAL AND METHODS: Records of the pounds of force necessary to separate each system were made at the beginning of testing, at pull 10 and then at every 50th pull until the 2000th pull was attained. All pulls were performed manually with a Shimpo force gauge. Absolute force (AF) and relative force (RF) were compared, AF being the force required at any pull to separate the overdenture device, whereas RF is the force required at the first pull. RESULTS: There was considerable difference of the force required at pull 1 for the ERA white, O-SO and ZAAG anchor systems, then the AccessPost overdenture, and finally the Flexi-Overdenture and ERA grey attachment systems. CONCLUSION: At pull 2000, there was no statistical difference between any of the attachments studied. The amount of force necessary to offer functional retention to a specific patient wearing an overdenture may vary considerably, depending on the many factors in fabricating the overdenture, and the age, strength, musculature, and the expectations of the patient.
机译:问题陈述:很少有研究涉及使用多个拉动循环的预制桩覆盖义齿的附着系统。目的:本研究测试了6个预制的覆盖义齿的附着系统(AccessPost覆盖义齿,ERA白色和ERA灰色,Flexi覆盖义齿,O-SO和ZAAG),以模拟在2000个拉拔周期中的磨损,并比较了在体外的固位力(磅) )。材料和方法:在测试开始时,在拉力10时,然后每50次拉力,直到达到2000次拉力,都记录了分离每个系统所需的磅力的记录。所有拉拔均使用Shimpo测力计手动进行。比较了绝对力(AF)和相对力(RF),AF是在任何拉动下分离覆盖义齿装置所需的力,而RF是在第一次拉动时所需的力。结果:对于ERA白色,O-SO和ZAAG锚固系统,然后是AccessPost覆盖义齿,最后是Flexi-Overdenture和ERA灰色固定系统,在拉力1处所需的力存在很大差异。结论:在拉力2000年,所研究的任何附件之间均无统计学差异。根据佩戴覆盖义齿的许多因素,年龄,力量,肌肉组织和患者的期望,为佩戴覆盖义齿的特定患者提供功能保持所需的力的大小可能会发生很大变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号