首页> 外文期刊>The Journal of Prosthetic Dentistry >An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.
【24h】

An in vitro comparison of retentive force and deformation of acetal resin and cobalt-chromium clasps.

机译:缩醛树脂和钴铬扣环的保持力和变形的体外比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

STATEMENT OF PROBLEM: The use of metal clasps on anterior teeth may cause esthetic problems. Recently, acetal resins have been used as an alternative tooth-colored denture clasp material to improve esthetics. However, there are few studies to support acetal resin use. PURPOSE: The purpose of this in vitro study was to compare the retentive force and deformation of acetal resin and cobalt-chromium clasps after 36 months of simulated clinical use. MATERIAL AND METHODS: Forty clasps each of acetal resin (1.2 or 2.0 mm thick) and cobalt-chromium (Dentorium)(1.2 mm thick) were fabricated using half-round standard prefabricated clasp patterns. The groups were further subdivided (n=10) into the type of tooth (premolar or molar metal model) and undercut (0.25 mm or 0.50 mm). The retentive force of the clasps was measured in distilled water by a specially designed insertion-removal testing apparatus with intervals corresponding to 0, 6, 12, 18, 24, 30, and 36 months of simulated clinical use of a removable partial denture. The distance between the clasp tips (mm) was measured with a microscope before and after the insertion-removal testing procedure. Comparison of the mean values of the retentive force (gram force) of the clasps and the distance (mm) between the clasp tips was conducted with 3-way analysis of variance and a Least Significant Difference (LSD) multiple range test (alpha=.05). RESULTS: The mean values of tensile load required to dislodge acetal resin clasps with 1.2-mm thickness (111.6 g or 0.11 N) and with 2.0-mm thickness (178.4 g or 1.75 N) was significantly lower than that to dislodge Co-Cr clasps (694.1 g or 6.81 N) (P<.001). The retentive force needed to dislodge all 3 types of clasps was significantly lower for the molar than premolar models and also lower for the models with 0.25-mm undercuts than for those with 0.50-mm undercuts (P<.001). After 36 months of simulated clinical use, there was evidence of deformation in the cobalt-chromium clasps but no deformation noted for the acetal resinclasps. The retentive force of cobalt-chromium clasps (297.4 g or 2.91 N) after deformation remained significantly higher (P<.001) than the retentive force of acetal resin clasps that were 1.2 mm (110.7 g or 1.08 N) and 2.0 mm thick (177.5 g or 1.74 N), respectively. CONCLUSION: Within the limitations of this study, the results suggest that both thicknesses of acetal resin clasps evaluated required less force for insertion and removal than Co-Cr clasps over a simulated 36-month period.
机译:问题陈述:在前牙上使用金属表扣可能会引起审美问题。最近,乙缩醛树脂已被用作替代牙齿色的义齿扣材料,以改善美学。但是,很少有研究支持使用缩醛树脂。目的:这项体外研究的目的是比较模拟临床使用36个月后乙缩醛树脂和钴铬扣的保持力和变形。材料和方法:使用半圆形标准预制扣环模型制作了40个扣环,分别是乙缩醛树脂(1.2或2.0 mm厚)和钴铬合金(Dentorium)(1.2 mm厚)。将这些组进一步细分(n = 10)到牙齿的类型(前磨牙或磨牙金属模型)和底切类型(0.25 mm或0.50 mm)。扣环的保持力是通过特殊设计的插入-去除测试设备在蒸馏水中进行测量的,间隔时间对应于模拟可移动部分义齿临床使用的0、6、12、18、24、30和36个月。在插入-移除测试程序之前和之后,用显微镜测量扣紧尖端之间的距离(mm)。通过三项方差分析和最小有效差(LSD)多范围检验(α=。)比较表扣的保持力(克力)的平均值和表扣尖端之间的距离(mm)的平均值。 05)。结果:移出厚度为1.2毫米(111.6 g或0.11 N)和厚度为2.0毫米(178.4 g或1.75 N)的乙缩醛树脂搭扣所需的拉伸载荷平均值明显低于移出Co-Cr搭扣的应力(694.1 g或6.81 N)(P <.001)。对于磨牙而言,移走所有3种类型的扣所需的保持力均显着低于前磨牙模型,而对于咬边为0.25mm的模型,其咬合力也比咬牙为0.50mm的模型更低(P <.001)。经过36个月的模拟临床使用后,钴铬扣环出现了变形,但乙缩醛树脂扣环没有发现变形。变形后钴铬扣环的固位力(297.4 g或2.91 N)仍然明显高于(1.2mm(110.7 g或1.08 N)和2.0 mm厚的乙缩醛树脂扣环的固位力(P <.001)( 177.5 g或1.74 N)。结论:在本研究的范围内,结果表明,在模拟的36个月内,所评估的两种厚度的乙缩醛树脂扣环的插入和移除力均小于Co-Cr扣环。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号