...
首页> 外文期刊>The Journal of Prosthetic Dentistry >Bond strengths of porcelain laminate veneers to tooth surfaces prepared with acid and Er,Cr:YSGG laser etching.
【24h】

Bond strengths of porcelain laminate veneers to tooth surfaces prepared with acid and Er,Cr:YSGG laser etching.

机译:用酸和Er,Cr:YSGG激光蚀刻制备的烤瓷贴面与牙齿表面的结合强度。

获取原文
获取原文并翻译 | 示例

摘要

STATEMENT OF PROBLEM: The erbium, chromium: yttrium, scandium, gallium, garnet (Er,Cr:YSGG) hydrokinetic laser system has been successful in the ablation of dental tissues. It has been reported that this system is also useful for preparing tooth surfaces for adhesion, but results to date have been controversial. PURPOSE: This in vitro study evaluated the bond strengths of porcelain laminate veneers to tooth surfaces after etching with acid and Er,Cr:YSGG laser conditioning.Material and method Forty extracted caries- and restoration-free human maxillary central incisors were used. The teeth were sectioned 2 mm below the cementoenamel junction. The crowns were embedded in autopolymerizing acrylic resin with the labial surfaces facing up. The labial surfaces were prepared with.05 mm reduction to receive porcelain veneers. The teeth were divided into 4 groups of 10 specimens. Thirty specimens received 1 of the following surface treatments before the bonding of IPS Empress 2 laminate veneers: (1) laser radiation from an Er,Cr:YSGG laser unit; (2) 37% orthophosphoric acid; and (3) 10% maleic acid. Ten specimens received no surface treatment and served as the control group. The veneers were bonded with dual-polymerizing resin, Variolink II. One microtensile specimen from each of the cervical and incisal thirds measuring 1.2 x 1.2 mm was prepared with a slow-speed diamond saw sectioning machine with a diamond-rim blade. These specimens were attached to opposing arms of the microtensile testing device with cyanoacrylate adhesive and fractured under tension at a crosshead speed of 1 mm/min, and the maximum load at fracture (Kg) was recorded. The data were analyzed with a 2-way analysis of variance and Tukey HSD tests (alpha=.05). RESULTS: No statistically significant differences were found among the bond strengths of veneers bonded to tooth surfaces etched with Er,Cr:YSGG laser (12.1 +/- 4.4 MPa), 37% orthophosphoric acid (13 +/- 6.5 MPa), and 10% maleic acid (10.6 +/- 5.6 MPa). The control group demonstrated the lowest bond strength values in all test groups. Statistically significant differences were found between the bond strengths of cervical and incisal sections (P<.001). CONCLUSION: In vitro microtensile bond strengths of porcelain laminate veneers bonded to tooth surfaces that were laser-etched showed results similar to orthophosphoric acid or maleic acid etched tooth surfaces.
机译:问题陈述:,、铬:钇,scan,镓,石榴石(Er,Cr:YSGG)流体动力学激光系统已经成功地消融了牙齿组织。据报道,该系统也可用于准备牙齿表面的附着力,但迄今为止的结果一直存在争议。目的:这项体外研究评估了经过酸和Er,Cr:YSGG激光调理后的烤瓷贴面与牙齿表面的粘结强度。材料和方法使用四十颗无龋和无修复的人类上颌中切牙。将牙齿切成低于牙釉质接合处2 mm的区域。牙冠嵌入阴唇朝上的自聚丙烯酸树脂中。准备的唇面缩小了0.05毫米,以容纳瓷贴面。将牙齿分为10组标本的4组。在IPS Empress 2层压薄板粘合之前,对30个样品进行了以下一种表面处理:(1)来自Er,Cr:YSGG激光单元的激光辐射; (2)37%正磷酸; (3)10%马来酸。十个标本未经表面处理,作为对照组。饰面用双聚合树脂Variolink II粘合。用带有金刚石边缘刀片的慢速金刚石锯切机,从每个颈椎和切牙的三分之二中分别测量一个1.2×1.2mm的微拉伸试样。将这些样品用氰基丙烯酸酯粘合剂附着在微拉伸试验装置的相对臂上,并以1mm / min的十字头速度在张力下断裂,并记录断裂时的最大载荷(Kg)。使用方差和Tukey HSD检验(alpha = .05)的2维分析对数据进行分析。结果:在用Er,Cr:YSGG激光(12.1 +/- 4.4 MPa),37%的正磷酸(13 +/- 6.5 MPa)和10蚀刻的牙齿上蚀刻的单板与牙齿表面的粘合强度之间没有统计学显着性差异%马来酸(10.6 +/- 5.6 MPa)。对照组在所有测试组中表现出最低的粘结强度值。宫颈和切牙的粘结强度之间存在统计学差异(P <.001)。结论:与激光蚀刻的牙齿表面粘结的烤瓷贴面的体外微拉伸粘结强度显示出与正磷酸或马来酸腐蚀的牙齿表面相似的结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号