Comparative tests of arbitrary and kinematic transverse horizontal axis recordings of mandibular movements.

机译:下颌运动的任意和运动横向横轴记录的比较测试。

获取原文
获取原文并翻译 | 示例

摘要

STATEMENT OF PROBLEM: The reliability of recording maxillomandibular relationships for articulator programming with a transverse horizontal axis determined arbitrarily with an arbitrary face-bow has not been verified against a kinematically determined and recorded transverse horizontal axis in an in vivo study. PURPOSE: The goal of this study was to determine the measuring accuracy of the Cadiax Compact system in a clinical series of tests and to determine whether there is a clinically significant difference between the 3-dimensional measurements recorded from kinematically and arbitrarily determined transverse horizontal axes. MATERIAL AND METHODS: Thirty subjects (11 women, 19 men; ages 21 to 26) participated in this study. Mandibular movement, the sagittal condylar inclination (SCI) angle, and the transversal condylar inclination (TCI) angle were recorded in each subject with the Cadiax Compact system, by use of first an arbitrarily and second a kinematically determined transverse horizontal axis. Asubset of 10 subjects was examined with another computerized axiograph, the Gamma Cadiax system. Measurements were made and recorded twice, on different days under similar circumstances. To compare the systems and measurement methods, the SCI measurements taken at 3- and 5-mm sagittal protrusion and the TCI taken at 3- and 5-mm mediotrusion were used. The lengths and characteristic curvatures of protrusion, opening, and mediotrusion tracings were determined for the evaluation as follows: tracing lengths (<8 mm, 8 to 12 mm, and >12 mm); degree of overlap of the excursive and incursive tracing; and tracing curvature. The intraclass correlation was used to compare angle values at the 95% confidence interval. To assess the track progression, kappa values were calculated. RESULTS: Repetition of the mandibular track inclination angles and the condylar movement pattern was highly reliable (intraclass correlation of >0.8) with the Cadiax Compact system. When the mandibular track inclinations determined kinematically and arbitrarily by the Gamma Cadiax and Cadiax Compact systems were compared, both systems demonstrated high reliability (ICC>0.8). The congruence results of the protrusion tracings from kinematic and arbitrary measurements with the Cadiax Compact system were as follows: strong congruence in quantity, characteristics, and horizontal tracing; only the quality diminished slightly (Kappa 0.46 in the first measurement, which still represented a clear congruence). The opening and mediotrusion tracings demonstrated fair to almost complete congruence in all parameters. CONCLUSION: Within the limitations of this study, the kinematic and arbitrary measurements of the Cadiax Compact system could be reliably used for articulator programming. The results suggest that arbitrarily determined posterior reference points may be comparable to a kinematically determined transverse horizontal axis.
机译:问题陈述:在体内研究中,还没有针对运动学确定和记录的横水平轴来验证用运动学确定并记录的横水平轴来记录咬合器编程的上下颌关系的可靠性,该横水平轴由任意面弓任意确定。目的:本研究的目的是在一系列临床试验中确定Cadiax Compact系统的测量精度,并确定从运动学和任意确定的横向水平轴记录的3维测量值之间是否存在临床上的显着差异。材料与方法:30名受试者(11名女性,19名男性; 21至26岁)参加了这项研究。使用Cadiax Compact系统在每个受试者中记录下颌运动,矢状con突倾角(SCI)角和横向dy突倾角(TCI)角,首先使用任意运动学确定的横向水平轴,然后使用运动学确定的横向水平轴。用另一台计算机化的轴流仪,Gamma Cadiax系统检查了10名受试者的亚组。在类似情况下的不同日期进行了两次测量并记录了两次。为了比较系统和测量方法,使用了在3毫米和5毫米矢状突处进行的SCI测量以及在3毫米和5毫米经中凸处进行的TCI。如下确定突出,开口和中间挤压迹线的长度和特征曲率,以进行评估:迹线长度(<8 mm,8至12 mm和> 12 mm);递归和递归跟踪的重叠程度;和跟踪曲率。类内相关用于比较95%置信区间的角度值。为了评估轨迹进展,计算了κ值。结果:Cadiax Compact系统的下颌轨道倾斜角度和con突运动模式的重复是高度可靠的(类内相关性> 0.8)。当比较由Gamma Cadiax和Cadiax Compact系统以运动学和任意方式确定的下颌轨迹倾斜度时,这两个系统都具有很高的可靠性(ICC> 0.8)。用Cadiax Compact系统进行的运动学和任意测量得出的突起迹线的一致性结果如下:在数量,特性和水平迹线方面一致性强;只有质量略有下降(第一次测量时的Kappa为0.46,这仍然代表了明显的一致性)。在所有参数上,开孔和中挤出的轨迹均显示出几乎完全一致。结论:在本研究的范围内,可以将Cadiax Compact系统的运动学和任意测量值可靠地用于咬合器编程。结果表明,任意确定的后参考点可能与运动学确定的横向水平轴相当。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号