首页> 外文期刊>Chromatographia >Selective Analysis of Dopamine Receptor Antagonist LE300 and its N-Methyl Metabolite in Mouse Sera at the Trace Level by HPLC-Fluorescence Detection
【24h】

Selective Analysis of Dopamine Receptor Antagonist LE300 and its N-Methyl Metabolite in Mouse Sera at the Trace Level by HPLC-Fluorescence Detection

机译:HPLC-荧光检测法对痕量水平的小鼠血清中多巴胺受体拮抗剂LE300及其N-甲基代谢产物的选择性分析

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

A highly selective, sensitive, and reliable high-performance liquid chromatography (HPLC) method was developed and validated for the simultaneous determination of a novel type of dopamine receptor antagonist LE300 and its N-methyl metabolite in mouse sera. LE300, its N-methyl metabolite, and verapamil (an internal standard) were detected using excitation and emission wavelengths of 275 and 340 nm, respectively. HPLC analysis using a deproteinization procedure was performed by injecting an aliquot of the supernatant into the chromatographic system. Chromatographic separation was achieved on a reversed-phase Spherisorb Cyano (CN) column with a mobile phase consisting of acetonitrile:50 mM phosphate buffer pH 3.5 (70:30, v/v) pumped at a flow rate of 1.0 mL min(-1). Regression analyses showed excellent linearity (r = 0.999) for concentrations of LE300 ranging from 4 to 500 ng mL(-1) and for concentrations of its N-methyl metabolite of 6-600 ng mL(-1). The HPLC-FLD method had limits of detection of 1.6 ng mL(-1) for LE300 and 2.4 ng mL(-1) for its N-methyl metabolite in mouse sera. The precision results, expressed as the intraday and interday relative standard deviation (RSD) values, ranged from 0.65 to 2.85 % (repeatability) and from 0.37 to 2.62 % (intermediate precision) for LE300 and its N-methyl metabolite, respectively; these values are in line with ICH guidelines. The assay was successfully applied in a pharmacokinetic study. The mean values of T (max) and C (max) were 2 h and 25.03 +/- A 5.60 ng mL(-1) for LE300 and 3 h and 19.92 +/- A 2.88 ng mL(-1) for its N-methyl metabolite, respectively.
机译:建立了一种高度选择性,灵敏且可靠的高效液相色谱(HPLC)方法,并验证了该方法可同时测定小鼠血清中的新型多巴胺受体拮抗剂LE300及其N-甲基代谢产物。 LE300,其N-甲基代谢产物和维拉帕米(内标)分别使用275和340 nm的激发和发射波长进行检测。通过将上清液的等分试样注入色谱系统中,进行了使用去蛋白步骤的HPLC分析。在反相Spherisorb Cyano(CN)色谱柱上进行色谱分离,流动相由乙腈:50 mM磷酸盐缓冲液pH 3.5(70:30,v / v)组成,流速为1.0 mL min(-1) )。回归分析显示LE300浓度为4至500 ng mL(-1)以及其N-甲基代谢产物浓度为6-600 ng mL(-1)时具有出色的线性(r = 0.999)。 HPLC-FLD方法在小鼠血清中对LE300的检出限为1.6 ng mL(-1),对其N-甲基代谢产物的检出限为2.4 ng mL(-1)。 LE300及其N-甲基代谢物的精密度结果以日内和日间相对标准偏差(RSD)值表示,范围分别为0.65至2.85%(重复性)和0.37至2.62%(中间精度);这些值符合ICH指南。该测定法成功地用于药代动力学研究。 T(max)和C(max)的平均值分别为LE300的2 h和25.03 +/- A 5.60 ng mL(-1)以及N的3 h和19.92 +/- A 2.88 ng mL(-1) -甲基代谢物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号