Total cholesterol monitoring in human plasma is one of the most important routine analysis performed in the clinical laboratory. Here we report a new capillary electrophoresis method for determination of plasma total cholesterol based on on-column enzymatic assay and laser-induced fluorescence detection. In this method, the capillary is used not only as a separation medium but also as the reaction chamber which minimizes the amount of samples and the consumption of the reagents. The whole procedure can be automated which minimizes the possible errors and saves experimental time. The analytical characteristics of the proposed method, such as linearity and repeatability of the peak area and the migration time, were evaluated. The RSD of the migration time and peak area were 1.0 and 3.5 % (intraday), and 2.2 and 2.9 % (interday), respectively. The obtained LOQ values were at the nanomolar concentration level, therefore the developed method is sufficient for determination and quantification of plasma total cholesterol.
机译:人血浆中总胆固醇的监测是临床实验室中最重要的常规分析之一。在这里,我们报告一种新的毛细管电泳方法,用于基于柱上酶促测定和激光诱导荧光检测的血浆总胆固醇测定。在这种方法中,毛细管不仅用作分离介质,而且用作反应室,从而最大程度地减少了样品量和试剂的消耗。整个过程可以自动化,从而最大程度地减少了可能的错误并节省了实验时间。评价了该方法的分析特性,例如峰面积的线性和重复性以及迁移时间。迁移时间和峰面积的RSD分别为1.0%和3.5%(日间),以及2.2%和2.9%(日间)。获得的LOQ值处于纳摩尔浓度水平,因此开发的方法足以确定和定量血浆总胆固醇。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号