...
首页> 外文期刊>The Annals of occupational hygiene. >Performance of High Flow Rate Personal Respirable Samplers When Challenged with Mineral Aerosols of Different Particle Size Distributions
【24h】

Performance of High Flow Rate Personal Respirable Samplers When Challenged with Mineral Aerosols of Different Particle Size Distributions

机译:高流速个人可吸入采样器在受到不同粒径分布的矿物气溶胶挑战时的性能

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

It is thought that the performance of respirable samplers may vary when exposed to dust aerosols with different particle sizes and wind speeds. This study investigated the performance of the GK 4.16 (RASCAL), GK 2.69, PPI 8, and FSP 10, high flow rate personal samplers when exposed to aerosols of mineral dust in a wind tunnel at two different wind speeds (1 and 2 m s(-1)) and orientations (towards and side-on to the source of emission). The mass median aerodynamic diameter of four aerosolized test dusts ranged from 8 to 25 A mu m with geometric standard deviations from 1.6 to 2 A mu m. The performance of each sampler type was compared with that of the SIMPEDS (Higgins-Dewell design) sampler. There was slight evidence to suggest that the performance of the FSP 10 is affected by the direction of the inlet relative to the air flow, although this was not significant when most respirable dust concentrations were compared, possibly due to the variability of paired dust concentration results. The GK 2.69, RASCAL, and PPI 8 samplers had similar performances, although the results when side-on to the emission source were generally slightly lower than the SIMPEDS. Despite slight differences between respirable dust concentrations the respirable crystalline silica values were not significantly different from the SIMPEDS. The GK family of cyclones obtained most precise results and more closely matched the SIMPEDS. A comparison with dust concentration results from previous calm air chamber studies (where wind speeds were < 0.4 m s(-1)) found that the relative performance between samplers was similar to those observed in this work indicating consistent performance relative to the SIMPEDS in both calm and moving air.
机译:人们认为,当暴露于具有不同粒径和风速的粉尘烟雾中时,可呼吸采样器的性能可能会发生变化。这项研究调查了GK 4.16(RASCAL),GK 2.69,PPI 8和FSP 10这些高流量个人采样器在风洞中以两种不同风速(1和2 ms( -1))和方向(朝着发射源的方向和侧面)。四种雾化测试粉尘的质量平均空气动力学直径范围为8到25 Aμm,几何标准偏差为1.6到2 Aμm。将每种采样器的性能与SIMPEDS(希金斯-德威尔设计)采样器的性能进行了比较。少量证据表明FSP 10的性能受进气口相对于气流方向的影响,尽管在比较大多数可吸入粉尘浓度时这并不重要,这可能是由于成对的粉尘浓度结果存在差异。 GK 2.69,RASCAL和PPI 8采样器具有类似的性能,尽管当侧向发射源时的结果通常略低于SIMPEDS。尽管可吸入粉尘浓度之间存在细微差异,但可吸入结晶二氧化硅的值与SIMPEDS并无显着差异。 GK旋风分离器系列获得了最精确的结果,并且与SIMPEDS更加匹配。与先前的平静空气室研究(风速<0.4 ms(-1))中的尘埃浓度进行比较后发现,采样器之间的相对性能与本工作中观察到的相对性能相似,这表明相对于SIMPEDS,在两个平静状态下性能均保持一致和移动的空气。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号