The performance of three filtering facepiece respirators (two models of N99 and one N95) challenged with an inert aerosol (NaCl) and three virus aerosols (enterobacteriophages MS2 and T4 and Bacillus subtilis phage)-all with significant ultrafine components-was examined using a manikin-based protocol with respirators sealed on manikins. Three inhalation flow rates, 30, 85, and 150 l min(-1), were tested. The filter penetration and the quality factor were determined. Between-respirator and within-respirator comparisons of penetration values were performed. At the most penetrating particle size (MPPS), >3% of MS2 virions penetrated through filters of both N99 models at an inhalation flow rate of 85 l min(-1). Inhalation airflow had a significant effect upon particle penetration through the tested respirator filters. The filter quality factor was found suitable for making relative performance comparisons. The MPPS for challenge aerosols was <0.1 mum in electrical mobility diameter for all tested respirators. Mean particle penetration (by count) was significantly increased when the size fraction of <0.1 mum was included as compared to particles >0.1 mum. The filtration performance of the N95 respirator approached that of the two models of N99 over the range of particle sizes tested ( approximately 0.02 to 0.5 mum). Filter penetration of the tested biological aerosols did not exceed that of inert NaCl aerosol. The results suggest that inert NaCl aerosols may generally be appropriate for modeling filter penetration of similarly sized virions.
机译:使用人体模型检查了三个带有惰性气溶胶(NaCl)和三个病毒气溶胶(噬菌体MS2和T4以及枯草芽孢杆菌噬菌体)的三个过滤式口罩呼吸器(两种型号的N99和一种N95)的性能-均使用超人体模型进行了检查人体模型的防毒面具的基于协议的协议。测试了三种吸入流速30、85和150 l min(-1)。确定了过滤器的穿透力和品质因数。进行呼吸器之间和呼吸器内渗透值的比较。在最穿透的粒径(MPPS)下,> 3%的MS2病毒体以85 l min(-1)的吸入流速穿过两个N99模型的过滤器。吸入气流对通过测试的呼吸器过滤器的颗粒渗透有重大影响。发现过滤器品质因数适合进行相对性能比较。对于所有测试过的呼吸器,用于气雾剂的MPPS的电迁移直径小于0.1微米。当包括小于0.1微米的尺寸分数时,与大于0.1微米的粒子相比,平均颗粒渗透(按计数)显着增加。在测试的粒径范围内(约0.02至0.5微米),N95防毒面具的过滤性能接近N99的两种型号。被测生物气溶胶的过滤器渗透率不超过惰性氯化钠气溶胶的渗透率。结果表明,惰性NaCl气雾剂通常可能适合于模拟大小相似的病毒粒子的过滤器渗透。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号