摘要

STUDY DESIGN: Experimental 3-factor design with repeated measures on all factors. OBJECTIVES: The purpose of this study was to determine the effectiveness of 3 prophylactic hyperextension elbow braces on limiting active and passive elbow extension before and after exercise. BACKGROUND: Prophylactic hyperextension elbow braces are used to protect the joint against excessive extension, but their effectiveness for this purpose has not been determined. METHODS AND MATERIALS: Twenty Division I intercollegiate football players (mean +/- SD age, 20.2 +/- 1.3 years; mean +/- SD height, 184.4 +/- 9.9 cm, mean +/- SD mass, 102.9 +/- 22.0 kg) completed all phases of the study. The Breg Functional Elbow Brace, PRO 470 Kendall Elbow Brace, and DonJoy Elbow Guard were tested both actively and passively before and after an isokinetic exercise session on a Biodex Multi-Joint Testing and Exercise Dynamometer. For all tests, the braces were set at a 30 degrees flexion limit angle. The exercise session consisted of 1 setof reciprocal elbow extension and flexion at an angular velocity of 360 degrees/s, totaling 1627 J of work. RESULTS: None of the braces limited elbow extension to the 30 degrees flexion limit. However, all of the braces were successful in preventing the elbow from reaching the vulnerable position of hyperextension. The Breg Functional Elbow Brace was the most effective for limiting elbow extension near its set angle, followed by the DonJoy Elbow Guard, and the PRO 470 Kendall Elbow Brace across all test conditions. CONCLUSION: The braces' effectiveness to limit motion is enhanced when limits are set higher than the desired angle of the protected motion.
机译:研究设计:实验性三因素设计,对所有因素进行重复测量。目的:本研究的目的是确定3种预防性过度伸展肘套对限制运动前后主动和被动肘部伸展的有效性。背景:预防性过度伸展肘套用于防止关节过度伸展,但尚未确定其有效性。方法和材料:20个I区大学生足球运动员(平均+/- SD年龄,20.2 +/- 1.3岁;平均+/- SD身高,184.4 +/- 9.9 cm,平均+/- SD质量,102.9 +/- 22.0公斤)完成了研究的所有阶段。在Biodex多关节测试和运动测功机上进行等速运动之前和之后,对Breg功能肘关节,PRO 470肯德尔肘关节和DonJoy肘护进行了主动和被动测试。对于所有测试,将撑杆设置为30度屈曲极限角。锻炼过程包括1组相互的肘部伸展和屈伸,其角速度为360度/秒,共工作1627J。结果:没有一个牙套将肘部伸展限制到30度屈曲极限。但是,所有的牙套都成功地防止了肘部到达过度伸展的脆弱位置。 Breg功能性肘部支撑对于将肘部伸展限制在其设定角度附近最为有效,其次是在所有测试条件下的DonJoy肘部防护装置和PRO 470 Kendall肘部支撑。结论:当限制值设置为高于保护动作的期望角度时,支撑件限制动作的效果会增强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号