Design and construction of a novel low-cost device to provide feedback on manually applied forces.

机译:一种新颖的低成本设备的设计和构造,可提供有关手动施加力的反馈。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY DESIGN: Design and evaluation, technical note. OBJECTIVES: To describe the design of a simple, low-cost device for providing feedback of manually applied forces to the cervical spine, and to assess the device against specific design criteria. BACKGROUND: The forces applied during manual therapy may vary by as much as 500% between practitioners. But consistency can be improved in students when they are provided with contemporaneous feedback. The current methods of providing feedback, however, are expensive, complex, and/or preclude their performance in a clinically relevant manner. METHODS: The design of the device was assessed in accordance of the following criteria: (1) ease of use, (2) low cost, (3) minimal interference with technique, (4) ability to provide feedback with suitable accuracy at forces up to 50 N, and (5) no requirement of specialized skills to construct. RESULTS: A device is described that interfaces with standard computers through the sound card and measures force, using thin, low-cost, force-sensing resistors. Evaluated against the design criteria, the device (1) is easy to set-up and use, (2) can be produced for under Dollars 30 US dollars, (3) creates minimal interference with performance of a variety of techniques, (4) has limits of agreement from -3.8 to 4.2 N for forces of 5 to 45 N and repeatability coefficients of +/- 2.0 N or 12%, and (5) can be constructed without specialized skills or knowledge. CONCLUSION: A device is described that fulfills most of the design criteria for providing feedback on forces for physical therapy students and may have applications in other fields.
机译:研究设计:设计和评估,技术说明。目的:描述一种简单,低成本的设备的设计,该设备可提供手动施加力到颈椎的反馈,并根据特定的设计标准评估该设备。背景:手动治疗过程中施加的力在医生之间的差异可能高达500%。但是,当学生获得同期反馈时,可以提高他们的一致性。然而,提供反馈的当前方法昂贵,复杂和/或妨碍它们以临床相关的方式执行。方法:根据以下标准评估了设备的设计:(1)使用简便,(2)成本低,(3)对技术的干扰最小,(4)在力向上时提供适当精度的反馈的能力到50 N,以及(5)不需要专门技能来构造。结果:描述了一种通过声卡与标准计算机连接并使用薄的低成本力感应电阻器测量力的设备。根据设计标准进行评估,该设备(1)易于安装和使用,(2)可以低于30美元的价格生产,(3)对各种技术性能的干扰最小,(4)对于5到45 N的力,一致性极限为-3.8到4.2 N,可重复性系数为+/- 2.0 N或12%,并且(5)可以在没有专门技能或知识的情况下构造。结论:描述了一种满足大多数设计标准的设备,该设备可为物理治疗学生提供有关力的反馈,并且可能在其他领域中得到应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号