Conventional myocardial perfusion PET tracers require onsite tracer production because of their short radioactive half-lives. To investigate the potential of a new (18)F-labeled pyridazinone analog ((18)F-BMS-747158-02), we characterized this tracer in a rat model of permanent and transient coronary occlusion using small-animal PET. METHODS: Myocardial (18)F-BMS-747158-02 distribution in healthy rats (n = 7), rats with transient (3-min) left coronary artery occlusion (n = 11), and rats with permanent left coronary occlusion (n = 11) was analyzed with a dedicated small-animal PET scanner. RESULTS: Normal hearts demonstrated intense and almost homogeneous tracer uptake throughout the left ventricle for more than 2 h. During permanent coronary occlusion, PET demonstrated perfusion defects, which remained unchanged (37.6% +/- 8.8%, 37.4% +/- 10.2%, and 36.2% +/- 9.8% left ventricle at 15, 45, and 115 min, respectively, after tracer injection). After transient ischemia, the induced defect size decreased significantly after reperfusion (16.2% +/- 9.3%, 6.0% +/- 6.5%, and 1.4% +/- 1.3% left ventricle). Tracer reinjection after transient ischemia resulted in normalization of the induced defect. CONCLUSION: Coronary occlusion yielded distinct myocardial (18)F-BMS-747158-02 uptake defects in the area of ischemia, which demonstrated normalization of activity after reperfusion and reinjection. These promising kinetic parameters may allow for assessment of flow using exercise-rest protocols similar to those used in combination with exercise and rest perfusion SPECT.
机译:传统的心肌灌注PET示踪剂由于放射性半衰期短,因此需要现场制造示踪剂。为了研究新的(18)F标记的哒嗪酮类似物((18)F-BMS-747158-02)的潜力,我们在使用小动物PET永久性和短暂性冠状动脉阻塞的大鼠模型中表征了该示踪剂。方法:在健康大鼠(n = 7),短暂(3分钟)左冠状动脉闭塞(n = 11)和永久性左冠状动脉闭塞(n)的大鼠中,心肌(18)F-BMS-747158-02分布= 11)用专用的小动物PET扫描仪进行分析。结果:正常心脏在整个左心室持续2 h以上表现出强烈且几乎均匀的示踪剂摄取。在永久性冠状动脉闭塞期间,PET表现出灌注缺陷,并保持不变(分别在15、45和115分钟时左心室分别为37.6%+/- 8.8%,37.4%+/- 10.2%和36.2%+/- 9.8%。 ,在注入示踪剂之后)。短暂性脑缺血后,再灌注后诱发的缺损大小显着减少(左心室分别为16.2%+/- 9.3%,6.0%+/- 6.5%和1.4%+/- 1.3%)。短暂性缺血后示踪剂的重新注入导致了诱导缺陷的正常化。结论:冠状动脉闭塞在缺血区域产生了明显的心肌(18)F-BMS-747158-02摄取缺陷,这表明再灌注和再注射后活性正常化。这些有希望的动力学参数可允许使用运动休息协议(类似于与运动和休息灌注SPECT结合使用的协议)评估血流。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号