PET Imaging of Serotonin Transporters with (11C)DASB: Test-Retest Reproducibility Using a Multilinear Reference Tissue Parametric Imaging Method.

机译:用(11C)DASB进行5-羟色胺转运蛋白的PET成像:使用多线性参考组织参数成像方法进行重测重现性。

获取原文
获取原文并翻译 | 示例
           

摘要

Parametric imaging of serotonin transporters (SERT) with (11)C-labeled 3-amino-4-(2-dimethylaminomethyl-phenylsulfanyl)benzonitrile ([(11)C]DASB) PET is a useful data analysis tool. The purpose of this study was to evaluate the reproducibility of measurements of SERT binding potential (BP) and relative blood flow (R(1)) by a 2-parameter multilinear reference tissue parametric imaging method (MRTM2) for human [(11)C]DASB studies. METHODS: Eight healthy subjects (3 men, 5 women; age, 26 +/- 9 y) underwent 2 [(11)C]DASB PET scans separated by 1 h on the same day (dose, 703 +/- 111 MBq). Parametric images of BP and R(1) were generated by MRTM2 using the cerebellum as a reference region. The k'(2) (clearance rate constant from the reference region) required by MRTM2 was estimated by the 3-parameter MRTM. Reproducibility of BP and R(1) measurements was evaluated by calculating bias (100 x (retest - test/test), variability (SD of the bias), and reliability (intraclass correlation coefficient = rho) for several representative regions of interest (ROIs). BP and R(1) were estimated for ROI time-activity curves fitted by MRTM2 and were compared with those based on the parametric images. RESULTS: The test-retest (0.066 +/- 0.013/0.06 +/- 0.011 min(-1)) MRTM k'(2) reproducibility was excellent with small bias (3%) and variability (6%) and high reliability (0.95). Retest BP values were consistently lower than those of test BP values in all regions (a mean negative bias of approximately 6%; P < 0.001). The test-retest BP variability was relatively small, ranging from 4% to 13%, with rho ranging from 0.44 to 0.85. In contrast to BP, test-retest R(1) values were similar with negligible bias of
机译:用(11)C标记的3-氨基-4-(2-二甲基氨基甲基-苯基硫烷基)苄腈([(11)C] DASB)PET对5-羟色胺转运蛋白(SERT)进行参数成像是一种有用的数据分析工具。这项研究的目的是通过2参数多线性参考组织参数成像方法(MRTM2)评估人[[11)C的SERT结合电位(BP)和相对血流量(R(1))的可重复性。 ] DASB研究。方法:八名健康受试者(3名男性,5名女性;年龄26 +/- 9岁)在同一天进行了2次[(11)C] DASB PET扫描,间隔1小时(剂量703 +/- 111 MBq) 。 BP和R(1)的参数化图像是由MRTM2使用小脑作为参考区域生成的。 MRTM2所需的k'(2)(相对于参考区域的清除率常数)由3参数MRTM估算。 BP和R(1)测量的可重复性通过计算偏差(100 x(重测-测试/测试),变异性(偏差的SD)和可靠性(类内相关系数= rho)来评估,用于几个感兴趣的代表性区域(ROI) )。估计BP和R(1)的MRTM2拟合的ROI时间-活动曲线,并与基于参数图像的ROI时间-活动曲线进行比较。结果:重新测试(0.066 +/- 0.013 / 0.06 +/- 0.011 min( -1))MRTM k'(2)的重现性极佳,偏差小(3%),变异性(6%)和高可靠性(0.95)。所有区域的再测试BP值始终低于测试BP值(a平均负偏差约为6%; P <0.001)。重测BP的变异性相对较小,范围为4%至13%,rho的范围为0.44至0.85。与BP相比,重测R(1 )值相似,偏差可忽略不计

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号