首页> 外文期刊>The Journal of Nuclear Medicine >Performance Evaluation of the 32-Module quadHIDAC Small-Animal PET Scanner.
【24h】

Performance Evaluation of the 32-Module quadHIDAC Small-Animal PET Scanner.

机译:32模块quadHIDAC小动物PET扫描仪的性能评估。

获取原文
获取原文并翻译 | 示例
           

摘要

The 32-module quadHIDAC is a commercial, high-resolution animal PET scanner, based on gas multiwire proportional chambers. METHODS: Several scanner parameters that characterize the performance of the system were evaluated in this study, such as spatial resolution, absolute sensitivity, scatter, and count rate performance. The spatial resolution has been determined with filtered back-projected images of a point source. A line source, a mouse phantom, and a rat phantom have been used to characterize the count rate performance. The scatter fraction and photon absorption have been measured with a mouse scatter phantom. The absolute sensitivity has been determined using a line source with aluminum shields of different thickness. RESULTS: Spatial resolution (full width at half maximum) offers values of 1.08, 1.08, and 1.04 mm in the radial, tangential, and axial directions, respectively. The maximum count rate is 370 kcps for a line source of 19 MBq activity. Registration of scattered coincidences is caused primarily by photons scattering in the large coincidence detectors. For a mouse-sized object, only 5% of the measured coincidences scatter inside the animal, whereas 32% of the coincidences scatter inside the detectors. Photon attenuation within a mouse phantom was 22%. After scatter corrections, the absolute sensitivity of the system is 15.2 cps/kBq for a point source and 13.7 cps/kBq for a 7.8-cm-long line source. The peak noise equivalent count rates are 67 kcps@209 kBq/mL for the mouse phantom and 52 kcps@96 kBq/mL for the rat phantom. Finally, a comparison has been made with the microPET R4, a commercial scintillation crystal-based PET camera. CONCLUSION: The results confirm that the quadHIDAC PET scanner, with its large cylindric field of view (165-mm diameter, 280-mm axial length), is particularly suitable for imaging small animals such as mice or rats.
机译:32模块的quadHIDAC是基于气体多线比例腔的商用​​高分辨率动物PET扫描仪。方法:本研究评估了表征系统性能的几个扫描仪参数,例如空间分辨率,绝对灵敏度,散射和计数率性能。空间分辨率已通过点源的滤波反投影图像确定。线源,鼠标幻像和大鼠幻像已用于表征计数率性能。散射分数和光子吸收已使用鼠标散射体模进行了测量。绝对灵敏度是使用带有不同厚度的铝屏蔽的线源确定的。结果:空间分辨率(半高全宽)在径向,切向和轴向分别提供1.08、1.08和1.04 mm的值。对于19 MBq活动的线源,最大计数率为370 kcps。散射巧合的配准主要是由大型巧合检测器中的光子散射引起的。对于鼠标大小的对象,只有5%的测量巧合散布在动物内部,而32%的巧合散布在检测器内部。小鼠幻像内的光子衰减为22%。经过散射校正后,对于点源,系统的绝对灵敏度为15.2 cps / kBq,对于7.8厘米长的线源,系统的绝对灵敏度为13.7 cps / kBq。小鼠体模的峰值噪声等效计数率为67 kcps @ 209 kBq / mL,大鼠体模为52 kcps @ 96 kBq / mL。最后,将其与基于商业闪烁晶体的PET相机microPET R4进行了比较。结论:结果证实了quadHIDAC PET扫描仪具有较大的圆柱视场(直径165mm,轴向长度280mm),特别适合对小动物(如小鼠或大鼠)成像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号