首页> 外文期刊>The Journal of laryngology and otology. >Impact of oxygen concentration and laser power on occurrence of intraluminal fires during shared-airway surgery: an investigation.
【24h】

Impact of oxygen concentration and laser power on occurrence of intraluminal fires during shared-airway surgery: an investigation.

机译:氧气浓度和激光功率对共享气道手术中腔内火灾发生的影响:一项调查。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: Airway fires pose a risk during laser microlaryngoscopy, and neurosurgical cotton patties, used to prevent tissue injury from stray laser beams, are a potential ignition source. Using a configuration approximating clinical practice, we experimentally assessed the relative impact of changing different 'fire triad' components on the occurrence of airway fires, in order to better inform patient care. METHODS: The relative effects of wet vs dry neurosurgical patties, oxygen concentration and laser power setting on the patty ignition time were studied in a cadaveric porcine model. Data were analysed using t-test and two-way analysis of variance. RESULTS: Dry patties ignited after 2.3 +/- 1.2 seconds (average +/- standard deviation) of continuous 5 W laser fire at 50 per cent oxygen concentration, compared with 63.9 +/- 27.8 seconds for wet patties under the same laser and oxygen settings (p < 0.0001). There was a statistically significant reduction in the time to patty ignition when laser power settings were increased from 5 to 7.5 W, but no further reductions occurred when the power was further increased to 10 W (p < 0.05; Tukey test for multiple comparisons; two-way analysis of variance). There was no significant reduction in the time to ignition between oxygen concentrations of 50 and 75 per cent, but the time to ignition fell significantly when the oxygen concentration was further increased to 100 per cent. CONCLUSION: We suggest that surgical patties should always be soaked and should be used for relatively short periods, in order to prevent drying. If at all possible clinically, prolonged laser use at high power settings and ventilation with 100 per cent oxygen should be avoided.
机译:目的:气道火灾在激光显微喉镜检查中有危险,神经外科棉饼可防止杂散激光束伤害组织,是潜在的着火源。使用近似于临床实践的配置,我们通过实验评估了更改不同“三合一”组件对气道火灾发生的相对影响,以便更好地为患者提供护理。方法:在尸体猪模型中研究了干式和干式神经外科小馅饼,氧气浓度和激光功率设置对小馅饼着火时间的相对影响。使用t检验和方差的双向分析来分析数据。结果:在氧气浓度为50%的情况下,连续5 W激光发射2.3 +/- 1.2秒(平均+/-标准偏差)后,干肉饼被点燃,而在相同的激光和氧气下,湿肉饼在63.9 +/- 27.8秒后被点燃设置(p <0.0001)。当激光功率设置从5 W增加到7.5 W时,小饼着火时间有统计上的显着减少,但是当功率进一步增加到10 W时,未发生进一步的减少(p <0.05; Tukey测试进行多次比较;两个方差分析)。氧浓度在50%到75%之间时,点火时间没有明显减少,但是当氧浓度进一步提高到100%时,点火时间大大减少。结论:我们建议手术肉饼应始终浸泡并应在较短的时间内使用,以防止干燥。如果在临床上完全可行,应避免在高功率设置下长时间使用激光,并避免使用100%的氧气进行通风。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号