A new, highly sensitive and selective gas chromatography method, using radiochemical detection (GC-RD) was developed for the selective determination of H-3-labelled deramciclane and its N-desmethyl metabolite in dog plasma. Inter-day accuracy and precision, as well as system suitability of the GC-RD method was investigated during the method validation. The calibration curve was proved to be linear (r = 0.9986) in a wide concentration range (13-1000 ngeqv mL(-1)) The lower limit of quantitation (LLOQ) was 13.7 ngeqv mL(-1),and the limit of the detection (LOD) was 1 ngeqv mL(-1). Using this new GC-RD method, plasma levels of H-3-labelled deramciclane and its metabolite were determined in dogs, after the administration of a single 10 mg kg(-1) oral dose. Pharmacokinetic curves and the calculated pharmacokinetic parameters were compared to those obtained using a previously elaborated gas chromatography-nitrogen selective detection method (GC-NPD) and to those obtained by measuring the plasma level of total radioactivity (liquid scintillation counting, LSC). Pharmacokinetic curves and the calculated pharmacokinetic parameters obtained with the two different gas chromatography detection methods (NPD and RD) showed good correlation. Comparison of these results to those acquired by total radioactivity measurement demonstrated that deramciclane was intensively metabolised. Moreover, the biological half-life (t(1/2)(beta)) of the unknown metabolites proved to be more than a magnitude longer than the half-life of the parent compound or that of N-desmethyl metabolite. [References: 17]
机译:开发了一种使用放射化学检测(GC-RD)的高灵敏度,选择性气相色谱新方法,用于在狗血浆中选择性测定H-3标记的地西环烷及其N-去甲基代谢产物。在方法验证期间,研究了日间准确性和精确度以及GC-RD方法的系统适用性。校准曲线在宽浓度范围(13-1000 ngeqv mL(-1))内被证明是线性的(r = 0.9986)。定量下限(LLOQ)为13.7 ngeqv mL(-1),其下限为检测(LOD)为1 ngeqv mL(-1)。使用这种新的GC-RD方法,在单次口服10 mg kg(-1)口服后,测定了狗中H-3标记的地西环烷及其代谢产物的血浆水平。将药代动力学曲线和计算出的药代动力学参数与使用先前阐述的气相色谱法-氮选择性检测方法(GC-NPD)获得的那些以及通过测量血浆总放射性水平(液体闪烁计数,LSC)获得的曲线进行比较。用两种不同的气相色谱检测方法(NPD和RD)获得的药代动力学曲线和计算的药代动力学参数显示出良好的相关性。将这些结果与通过总放射性测量获得的结果进行比较,结果表明地拉西clane被强烈代谢。而且,未知代谢物的生物半衰期(t(1/2)β)被证明比母体化合物或N-去甲基代谢物的半衰期更长。 [参考:17]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号