Computerized analysis of fetal heart rate variability using the matching pursuit technique as an indicator of fetal hypoxia during labor.

机译:使用匹配追踪技术作为分娩时胎儿缺氧的指标,对胎儿心率变异性进行计算机分析。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To determine whether the computerized analysis of fetal heart rate variability with the new matching pursuit technique can indicate fetal distress during labor. STUDY DESIGN: Eighty women were studied during the intrapartum period with external cardiotocography. In all cases, cord arterial pH and 5-min Apgar Scores were evaluated. Six cases that presented large segments of missing data were excluded from the study. The remaining 74 women were divided into two groups; 32 women with normal (Group A) and 42 women with non-reassuring FHR tracings (group B). Group B was divided in subgroup BI, including 24 women with pH > 7.20, and BII, including 18 women with pH < 7.20. In order to evaluate the FHR fluctuations, in different frequency ranges, we applied an adaptive time-frequency method, called Matching Pursuit. We estimated the power of the FHR signal in four frequency ranges. RESULTS: The 5-min Apgar Scores were significantly lower in both subgroup BI and subgroup BII (p = 0.003 and p = 0.003 respectively). The Low Low Frequency (LLF) parameter appears to recognize better the cases with lower pH (sensitivity 78.5%, specificity 52.3%) than the cases with non-reassuring FHR (66.6%, 56.2). The sensitivity and specificity of the Very Low Frequency (VLF) parameter were 72.2% and 59% respectively in recognizing the cases with lower pH and 64.2% and 53.1% in recognizing non-reassuring FHR. CONCLUSION: Fetal hypoxia during labor can be recognized using the MP technique for the analysis of FHR signal power in the VLF and LLF frequency ranges. Since the analysis is feasible in real-time, it can be a useful tool for the intrapartum evaluation of fetal well-being.
机译:目的:确定使用新的匹配追踪技术对胎儿心率变异性进行计算机分析是否可以指示分娩时的胎儿窘迫。研究设计:对80名妇女在分娩期进行了体外心动图检查。在所有情况下,均评估脐带动脉pH和5分钟Apgar评分。该研究排除了六例出现大量缺失数据的案例。其余的74名妇女分为两组。 32例正常(A组)妇女和42例FHR描记不安的妇女(B组)。 B组分为BI组,包括24名pH值> 7.20的女性和BII,包括18名pH <7.20的女性。为了评估不同频率范围内的FHR波动,我们应用了一种自适应的时频方法,称为Matching Pursuit。我们在四个频率范围内估算了FHR信号的功率。结果:BI亚组和BII亚组的5分钟Apgar得分均显着降低(分别为p = 0.003和p = 0.003)。低低频(LLF)参数似乎比不放心FHR的情况(66.6%,56.2)能更好地识别pH值较低的情况(敏感性78.5%,特异性52.3%)。在识别pH值较低的病例中,甚低频(VLF)参数的灵敏度和特异性分别为72.2%和59%,在识别不安定的FHR时分别为64.2%和53.1%。结论:使用MP技术分析VLF和LLF频率范围内的FHR信号功率可以识别出分娩过程中的胎儿缺氧。由于该分析是实时可行的,因此它可能是评估胎儿健康状况的有效手段。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号