Influence of gestational age and fetal heart rate on the fetal mechanical PR interval.

机译:胎龄和胎儿心率对胎儿机械PR间隔的影响。

获取原文
获取原文并翻译 | 示例

摘要

Objective: The fetal mechanical PR interval obtained via pulsed Doppler has previously been demonstrated to correlate with electrocardiographic PR interval measured in the neonate. We sought to further analyze the influence of fetal heart rate and gestational age upon the fetal mechanical PR interval. Methods: We searched our database for mechanical PR intervals, which were obtained during fetal echocardiography performed in our antenatal diagnostic unit. We included fetuses with a normal cardiac structural survey. The mechanical PR interval is measured from the A wave of the mitral valve to the beginning of ventricular systole corresponding to the opening of the aortic valve. Linear regression curves were generated to examine the correlation of mechanical PR interval with gestational age and fetal heart rate. Analysis of variance was used to compare the mean variation across three gestational age groups: 17-21.9 weeks (n = 24), 22-25.9 weeks (n = 52) and 26-38 weeks (n = 20). Results: Mechanical PR intervals were measured in 96 fetuses with normal fetal echocardiography. The mechanical PR interval was 123.9 +/- 10.3 ms (mean +/- SD), with a range of 90-150 ms. Linear regression curves correlating mechanical PR interval with fetal heart rate and gestational age demonstrated a flat slope with R = 0.016, p = 0.22 and R = 0.0004, p = 0.85, respectively. The mechanical PR interval measured over the three gestational ages was as follows (mean +/- SD): 122.3 +/- 10.5 ms for 17-21.9 weeks; 125.0 +/- 9.6 ms for 22-25.9 weeks; and 123.1 +/- 11.9 ms for 26-38 weeks. Analysis of variance revealed no difference among the mechanical PR interval means measured over the three gestational age groups (p = 0.53). Conclusions: Fetal mechanical PR interval ranges from 90 to 150 ms in fetuses with sonographically normal fetal cardiac structure and rate. The mechanical PR interval appears to be independent of gestational age and fetal heart rate.
机译:目的:先前已证明通过脉冲多普勒获得的胎儿机械PR间隔与新生儿测得的心电图PR间隔相关。我们试图进一步分析胎儿心率和胎龄对胎儿机械PR间隔的影响。方法:我们在数据库中搜索了机械PR间隔,该间隔是在产前诊断部门进行的胎儿超声心动图检查中获得的。我们纳入了具有正常心脏结构检查结果的胎儿。机械PR间隔是从二尖瓣的A波到对应于主动脉瓣打开的心室收缩开始测量的。生成线性回归曲线以检查机械PR间隔与胎龄和胎儿心率的相关性。方差分析用于比较三个胎龄组的平均差异:17-21.9周(n = 24),22-25.9周(n = 52)和26-38周(n = 20)。结果:正常胎儿超声心动图测量了96例胎儿的机械PR间隔。机械PR间隔为123.9 +/- 10.3毫秒(平均+/- SD),范围为90-150毫秒。将机械PR间隔与胎儿心率和胎龄相关联的线性回归曲线显示出平坦斜率分别为R = 0.016,p = 0.22和R = 0.0004,p = 0.85。在三个胎龄期测量的机械PR间隔如下(平均+/- SD):122.3 +/- 10.5 ms,持续17-21.9周; 22-25.9周为125.0 +/- 9.6毫秒;在26-38周内为123.1 +/- 11.9毫秒。方差分析显示,在三个胎龄组中测量的机械PR间隔平均值之间无差异(p = 0.53)。结论:胎儿超声检查的心脏结构和频率正常,胎儿的机械PR间隔在90到150 ms之间。机械性PR间隔似乎与胎龄和胎儿心率无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号